The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Distributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid
Abstract
In this paper, a single-phase high-frequency AC (HFAC) microgrid is shown as a novel solution towards integrating renewable energy sources in a distributed generation system. Better utilization of the Microgrid is achieved by solving power flow and power quality issues using p-q theory-based active filtering called universal active power line conditioner and unified power quality conditioner, respectively. A distributed intelligent energy management system (DIEMS) is implemented to optimize operating costs. As the optimization greatly depends on the power generation and the power output from renewable sources strongly depends on the weather, the forecast of power generation is required for DIEMS. A Fuzzy ARTMAP neural network is used to predict hourly day-type outputs based on which generation can be forecasted. Depending on the forecast, an optimization scheme is developed utilizing linear programming along with heuristics. The results obtained show the successful implementation of HFAC Microgrid with adequate power flow and power quality control, as well as the optimization of operation cost by the DIEMS with Fuzzy ARTMAP-based day-type forecasting. The improvement in the battery life is also achieved due to optimization of storage charge states using the proposed DIEMS
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A massively parallel architecture for a self-organizing neural pattern recognition machine
Carpenter, G. A., & Grossberg, S. (1987) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(87)80014-2 · Cited by 2,525
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Guerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965
Guo, F., Wen, C., Mao, J., & Song, Y.-D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2379211 · Cited by 678
Majumder, R., Ghosh, A., Ledwich, G., & Zare, F. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2034666 · Cited by 332
Bui, V., Le, N. T., Nguyen, V. H., Kim, J., & Jang, Y. M. (2021) · Electronics · doi:10.3390/electronics10091026 · Cited by 25
Metadata
- Authors
- Chakraborty, S., Weiss, M. D., & Simoes, M. G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2007-02
- Volume
- 54
- Issue
- 1
- Pages
- 97-109
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2135178255
- Cited by
- 413
- References
- 1
- FWCI
- 35.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid. https://app.cochat.ai/papers/10.1109/tie.2006.888766
- The paper
- Chakraborty, S., Weiss, M. D., & Simoes, M. G. (2007). Distributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2006.888766
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.