Power Management and Power Flow Control With Back-to-Back Converters in a Utility Connected Microgrid
Open accessAbstract
This paper proposes a method for power flow control between utility and microgrid through back-to-back converters, which facilitates desired real and reactive power flow between utility and microgrid. In the proposed control strategy, the system can run in two different modes depending on the power requirement in the microgrid. In mode-1, specified amount of real and reactive power are shared between the utility and the microgrid through the back-to-back converters. Mode-2 is invoked when the power that can be supplied by the distributed generators (DGs) in the microgrid reaches its maximum limit. In such a case, the rest of the power demand of the microgrid has to be supplied by the utility. An arrangement between DGs in the microgrid is proposed to achieve load sharing in both grid connected and islanded modes. The back-to-back converters also provide total frequency isolation between the utility and the microgrid. It is shown that the voltage or frequency fluctuation in the utility side has no impact on voltage or power in microgrid side. Proper relay-breaker operation coordination is proposed during fault along with the blocking of the back-to-back converters for seamless resynchronization. Both impedance and motor type loads are considered to verify the system stability. The impact of dc side voltage fluctuation of the DGs and DG tripping on power sharing is also investigated. The efficacy of the proposed control arrangement has been validated through simulation for various operating conditions. The model of the microgrid power system is simulated in PSCAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Operation of a Multiagent System for Microgrid Control
Dimeas, A. L., & Hatziargyriou, N. D. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852060 · Cited by 1,031
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Brahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.820204 · Cited by 679
Distributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid
Chakraborty, S., Weiss, M. D., & Simoes, M. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888766 · Cited by 413
Nikkhajoei, H., & Lasseter, R. H. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385805 · Cited by 297
Impacts of distributed generation on power system transient stability
Slootweg, J. G., & Kling, W. L. (2003) · IEEE Power Engineering Society Summer Meeting, · doi:10.1109/pess.2002.1043465 · Cited by 259
Cited by
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Basak, P., Chowdhury, S., Halder nee Dey, S., & Chowdhury, S. P. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.043 · Cited by 508
Pippia, T., Sijs, J., & De Schutter, B. (2020) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2019.2945023 · Cited by 58
Metadata
- Authors
- Majumder, R., Ghosh, A., Ledwich, G., & Zare, F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-05
- Volume
- 25
- Issue
- 2
- Pages
- 821-834
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W236509347
- Cited by
- 332
- References
- 12
- FWCI
- 24.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Power Management and Power Flow Control With Back-to-Back Converters in a Utility Connected Microgrid. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2034666
- The paper
- Majumder, R., Ghosh, A., Ledwich, G., & Zare, F. (2010). Power Management and Power Flow Control With Back-to-Back Converters in a Utility Connected Microgrid. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2034666
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.