The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Abstract
A controlled power electronic converter can cause local instabilities when interacting with other dynamic subsystems in a power system. Oscillations at a certain frequency cannot, however, build up if the converter differential input admittance has a positive conductance (real part) at that frequency, since power is then dissipated. In this paper, input-admittance expressions for a voltage-source converter are derived. It is seen how the admittance can be shaped in order to get a positive real part in the desired frequency regions by adjusting the controller parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissipative dynamical systems part I: General theory
Willems, J. C. (1972) · Archive for Rational Mechanics and Analysis · doi:10.1007/bf00276493 · Cited by 3,250
Dissipative dynamical systems Part II: Linear systems with quadratic supply rates
Willems, J. C. (1972) · Archive for Rational Mechanics and Analysis · doi:10.1007/bf00276494 · Cited by 991
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
Subsynchronous Resonance in Power Systems
Anderson, P. M., Agrawal, B. L., & Ness, J. E. V. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546505 · Cited by 426
Out of control because of harmonics-an analysis of the harmonic response of an inverter locomotive
Möllerstedt, E., & Bernhardsson, B. (2000) · IEEE Control Systems · doi:10.1109/37.856180 · Cited by 302
Cited by
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Self-citationHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Metadata
- Authors
- Harnefors, L., Bongiorno, M., & Lundberg, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2007-12
- Volume
- 54
- Issue
- 6
- Pages
- 3323-3334
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2163501722
- Cited by
- 1,117
- References
- 5
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.