Modeling and Control of Six-Phase Symmetrical Induction Machine Under Fault Condition Due to Open Phases
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper introduces a new fault-tolerant operation method for a symmetrical six-phase induction machine (6PIM) when one or several phases are lost. A general decoupled model of the induction machine with up to three open phases is given. This model illustrates the existence of a pulsating torque when phases are opened. Then, a new control method reducing the pulsating torque and the motor losses is proposed in order to improve the drive performances. The proposed method is compared to two other existing techniques. The simulation and experimental results obtained on a dedicated test-rig confirm the validity and the efficiency of the proposed method for a fault-tolerant symmetrical 6PIM drive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Space vector PWM control of dual three-phase induction machine using vector space decomposition
Zhao, Y., & Lipo, T. A. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464525 · Cited by 1,406
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374
Disturbance-free operation of a multiphase current-regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.315238 · Cited by 372
Disturbance free operation of a multiphase current regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (2002) · Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting · doi:10.1109/ias.1993.298884 · Cited by 318
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Modeling and control of a multi-phase induction machine with structural unbalance
Zhao, Y., & Lipo, T. A. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.537028 · Cited by 216
Modeling and control of a multi-phase induction machine with structural unbalance
Zhao, Y., & Lipo, T. A. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.537009 · Cited by 198
Ryu, H.-M., Kim, J.-W., & Sul, S.-K. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876074 · Cited by 187
Fault-Tolerant Operating Strategies Applied to Three-Phase Induction-Motor Drives
Mendes, A. M. S., & Cardoso, A. J. M. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885137 · Cited by 150
Multiple-phase permanent magnet synchronous machine supplied by VSIs, working under fault conditions
Martin, J., Meibody‐Tabar, F., & Davat, B. (2002) · doi:10.1109/ias.2000.882111 · Cited by 43
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Che, H. S., Duran, M. J., Levi, E., Jones, M., Hew, W.-P., & Rahim, N. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293195 · Cited by 394
Guzman, H., Duran, M. J., Barrero, F., Bogado, B., & Toral, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2289882 · Cited by 258
Baneira, F., Doval-Gandoy, J., Yepes, A. G., Lopez, O., & Perez-Estevez, D. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2620426 · Cited by 173
Lin, F.-J., Hung, Y.-C., & Tsai, M.-T. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2238877 · Cited by 145
“fault may occur due to the sensor fault such as strain gauge sensor, current sensor, and voltage sensor faults [21], [22] or the broken plant such as motors with open phases [23]–[26].”
BackgroundMethodBaudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
“This control may be performed in the stator reference frame [10] or in the rotor one [38].”
Background
Metadata
- Authors
- Kianinezhad, R., Nahid-Mobarakeh, B., Baghli, L., Betin, F., & Capolino, G.-A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-05
- Volume
- 55
- Issue
- 5
- Pages
- 1966-1977
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2135023935
- Cited by
- 266
- References
- 11
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.