Fault Tolerant and Minimum Loss Control of Double-Star Synchronous Machines Under Open Phase Conditions
The DOI matches its Crossref record.
Abstract
In this paper, a new method for filtering the torque pulsations is proposed for double-star permanent magnet synchronous machines under fault conditions. The machine is supplied by two independent electric sources via two voltage source inverters. The proposed method deals with the case where an open-circuit fault occurs. To reduce the torque pulsations, the usual solution consists in supplying only the healthy star winding. Here, we propose to supply not only the healthy winding, but also the two remaining phases of the other star winding by the healthy legs of the faulty inverter. The stator current waveforms can be easily determined to minimize the copper losses while reducing the torque pulsations. Simulation and experimental results confirm the efficiency of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Che, H. S., Duran, M. J., Levi, E., Jones, M., Hew, W.-P., & Rahim, N. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293195 · Cited by 394
Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Jin, L., Mao, Y., Wang, X., Shi, P., Lu, L., & Wang, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3222224 · Cited by 103
Baudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92
Self-citationDieterle, O., Greiner, T., & Heidrich, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835422 · Cited by 25
“In most studies of fault-tolerant drives with PMSM, the rotor has surface-mounted magnets (Ld = Lq ), reluctance torque is omitted, and magnetic saturation is neglected as well [9]–[11].”
BackgroundMethod
Metadata
- Authors
- Shamsi-Nejad, M.-A., Nahid-Mobarakeh, B., Pierfederici, S., & Meibody-Tabar, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-05
- Volume
- 55
- Issue
- 5
- Pages
- 1956-1965
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2133114219
- Cited by
- 160
- References
- 0
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.