The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Long-Lifetime Power Inverter for Photovoltaic AC Modules
Abstract
This paper presents a power inverter tailored for low-power photovoltaic (PV) systems. The inverter features high reliability, thanks to a circuit topology that obviates aluminum electrolytic capacitors from the circuit. Moreover, all components, including logic and control, have been designed to exhibit high reliability at high temperatures. Three conversion stages form the power topology. First, a full bridge connected to a high-frequency transformer and a full-bridge rectifier amplifies the voltage of the PV panel to approximately 475 V. This stage is controlled by using a phase-shift pulsewidth-modulation controller that permits zero-voltage switching, thereby minimizing losses. Second, a buck converter is connected in series with the rectifier and is controlled by using current mode in order to shape the current injection into a rectified sine wave. Last, a full bridge is operated at line frequency to unfold the current injection. The amplification stage has a proportional compensator that maintains the voltage at the PV terminals constant. The current injection stage has a proportional-derivative compensator that controls the amplitude of the grid current so that the dc-link average voltage is maintained constant. Experimental results show that the peak efficiency of the system is 89%, and the total current harmonic distortion is below 5%. Finally, analyses show a designed lifetime of approximately ten years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Development of a microcontroller-based, photovoltaic maximum power point tracking control system
Koutroulis, E., Kalaitzakis, K. C., & Voulgaris, N. C. (2001) · IEEE Transactions on Power Electronics · doi:10.1109/63.903988 · Cited by 1,417
A Cost-Effective Single-Stage Inverter With Maximum Power Point Tracking
Chen, Y., & Smedley, K. M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833458 · Cited by 317
New Zero-Voltage-Switching Phase-Shift Full-Bridge Converter With Low Conduction Losses
Koo, G.-B., Moon, G., & Youn, M.-J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.841063 · Cited by 145
Improved small-signal analysis for the phase-shifted PWM power converter
Schutten, M. J., & Torrey, D. A. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809539 · Cited by 79
Cited by
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Transitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693
Li, W., Gu, Y., Luo, H., Cui, W., He, X., & Xia, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2399278 · Cited by 671
Krein, P. T., Balog, R. S., & Mirjafari, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2186640 · Cited by 520
Shenoy, P. S., Kim, K. A., Johnson, B. B., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2211082 · Cited by 460
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2264540 · Cited by 449
Design for reliability of power electronic systems
Wang, H., Ma, K., & Blaabjerg, F. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6388833 · Cited by 313
A Modular Grid-Connected Photovoltaic Generation System Based on DC Bus
Zhang, L., Sun, K., Xing, Y., Feng, L., & Ge, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2064337 · Cited by 275
Zhang, P., Li, W., Li, S., Wang, Y., & Xiao, W. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.010 · Cited by 265
Metadata
- Authors
- Rodriguez, C., & Amaratunga, G. A. J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-07
- Volume
- 55
- Issue
- 7
- Pages
- 2593-2601
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2109113878
- Cited by
- 258
- References
- 5
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.