Current Sensor Fault Detection, Isolation, and Reconfiguration for Doubly Fed Induction Generators
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Fault tolerance is gaining growing interest to increase the reliability and availability of distributed energy sources. Current sensor fault detection, isolation, and reconfiguration are presented for a voltage-oriented controlled doubly fed induction generator, which is mainly used in wind turbines. The focus of this analysis is on the isolation of the faulty sensor and the actual reconfiguration. During a short period of open-loop operation, the fault is isolated by looking at residuals calculated from observed and measured signals. Then, replacement signals from observers are used to reconfigure the drive and reenter closed-loop control. Laboratory measurement results are included to prove that the proposed concept leads to good results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240 · cited 2×
“Sensor-fault-tolerant control for electric vehicles has been treated in [15]–[18].”
Background
Cited by
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Luenberger observers are used in [39] and [40] to provide residuals for fault diagnosis.”
MethodOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Metadata
- Authors
- Rothenhagen, K., & Fuchs, F. W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-10
- Volume
- 56
- Issue
- 10
- Pages
- 4239-4245
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2101401941
- Cited by
- 152
- References
- 1
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Sensor Fault Detection, Isolation, and Reconfiguration for Doubly Fed Induction Generators. https://app.cochat.ai/papers/10.1109/tie.2009.2017562
- The paper
- Rothenhagen, K., & Fuchs, F. W. (2009). Current Sensor Fault Detection, Isolation, and Reconfiguration for Doubly Fed Induction Generators. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2017562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.