Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record.

Extended Operation of Cascade Multicell Converters Under Fault Condition

Open access
Lezana, P., Ortiz, G.·2009·IEEE Transactions on Industrial Electronics

Abstract

Multilevel converters are an interesting alternative for high power drives, due to their good quality output signals. Despite their advantages, the large number of components required increases the fault probability. Among the multilevel topologies, the cascade multicell converter presents advantages when operating under internal fault conditions, due to its high modularity. Previous works proposed to compensate the unbalanced operation due to a fault by changing the canonical fundamental output phase shift to precalculated angles, depending on the fault condition. This solution assumes that, if the maximum output phase voltage on each leg is used, the maximum line-to-line voltage will be at a maximum as well. This paper shows how this assumption is not always valid and presents the optimum angles and modulation indexes that must be used in order to obtain the maximum balanced load voltages.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2009.2019771

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Lezana, P., & Ortiz, G.
Venue
IEEE Transactions on Industrial Electronics
Published
2009-07
Volume
56
Issue
7
Pages
2697-2703
ISSN
0278-0046 (ISSN-L)
OpenAlex
W2106895166
Cited by
219
References
0
FWCI
6.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extended Operation of Cascade Multicell Converters Under Fault Condition. https://app.cochat.ai/papers/10.1109/tie.2009.2019771
The paper
Lezana, P., & Ortiz, G. (2009). Extended Operation of Cascade Multicell Converters Under Fault Condition. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2019771

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.