Hybrid Electric Vehicle Power Management Solutions Based on Isolated and Nonisolated Configurations of Multilevel Modular Capacitor-Clamped Converter
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents the various configurations of a multilevel modular capacitor-clamped converter (MMCCC), and it reveals many useful and new formations of the original MMCCC for transferring power in either an isolated or nonisolated manner. The various features of the original MMCCC circuit are best suited for a multibus system in future plug-in hybrid or fuel-cell-powered vehicles' drive train. The original MMCCC is capable of bidirectional power transfer using multilevel modular structure with capacitor-clamped topology. It has a nonisolated structure, and it offers very high efficiency even at partial loads. This circuit was modified to integrate single or multiple high-frequency transformers by using the intermediate voltage nodes of the converter. On the other hand, a special formation of the MMCCC can exhibit dc outputs offering limited isolation without using any isolation transformer. This modified version can produce a high conversion ratio from a limited number of components and has several useful applications in providing power to multiple low-voltage loads in a hybrid or electric automobile. This paper will investigate the origin of generating ac outputs from the MMCCC and shows how the transformer-free version can be modified to create limited isolation from the circuit. In addition, this paper will compare various modified forms of the MMCCC topology with existing dc-dc converter circuits from compactness and component utilization perspectives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emadi, A., Lee, Y. J., & Rajashekara, K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922768 · Cited by 1,461 · cited 1×
“This isolation is found essential when the converter needs to be integrated between low-voltage (LV) and high-voltage (HV) buses [1]–[5], and the present trend indicates that this multivoltage bus architecture will be very common in plug-in hybrid or future fuel-cell automobiles [1], [3].”
BackgroundA natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices
Li, H., Peng, F. Z., & Lawler, J. S. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808965 · Cited by 296 · cited 1×
“A capacitor-clamped converter [6]‐[8] usually has more transistors for a certain conversion ratio (CR) compared to the classical IETM dc‐dc converters [ 9 ]‐[16] commonly used in”
Method
Cited by
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Efficiency Analysis of Drive Train Topologies Applied to Electric/Hybrid Vehicles
Estima, J. O., & Marques Cardoso, A. J. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2186993 · Cited by 307
Study of a non-isolated bidirectional DC–DC converter
Lin, C. ‐., Yang, L. ‐., & Wu, G. W. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2012.0338 · Cited by 180
Chang, F., Ilina, O., Lienkamp, M., & Voss, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2854756 · Cited by 111
Metadata
- Authors
- Khan, F. H., Tolbert, L. M., & Webb, W. E.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-08
- Volume
- 56
- Issue
- 8
- Pages
- 3079-3095
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2142521097
- Cited by
- 75
- References
- 2
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.