The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Performance Evaluation of Fault-Tolerant Neutral-Point-Clamped Converters
Abstract
This paper presents a study of the fault tolerance capacity of a neutral-point-clamped converter. Different faults in power semiconductors are considered, and the available postfault states of the converter are shown. In regard of the operation limits, two possible solutions are presented. In these solutions, adding a reduced number of additional components, the behavior of the converter when a switch fails improves considerably. Furthermore, an analysis of the neutral-point voltage balancing conditions after a fault and reconfiguration of the system is also evaluated. Experimental results that prove the correct operation of the proposed topologies are shown.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The age of multilevel converters arrives
Franquelo, L. G., Rodríguez, J., Leon, J. I., Kouro, S., Portillo, R., & Martín-Prats, M. A. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,066
A new multilevel PWM method: a theoretical analysis
Carrara, G. R., Gardella, S., Marchesoni, M., Salutari, R., & Sciutto, G. (1992) · IEEE Transactions on Power Electronics · doi:10.1109/63.145137 · Cited by 1,088
The Active NPC Converter and Its Loss-Balancing Control
Bruckner, T., Bernet, S., & Güldner, H. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.847586 · Cited by 737
Teichmann, R., & Bernet, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847285 · Cited by 578
Evaluation of the Low-Frequency Neutral-Point Voltage Oscillations in the Three-Level Inverter
Pou, J., Pindado, R., Boroyevich, D., & Rodríguez, P. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.858723 · Cited by 300
Self-citationOperation of a Medium-Voltage Drive Under Faulty Conditions
Rodríguez, J., Hammond, P. W., Pontt, J. O., Musalem, R., Lezana, P., & Escobar, M.-J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
A Unique Fault-Tolerant Design for Flying Capacitor Multilevel Inverter
Kou, X., Corzine, K. A., & Familiant, Y. L. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830037 · Cited by 185
A Multilevel Converter Topology With Fault-Tolerant Ability
Chen, A., Hu, L., Chen, L., Deng, Y., & He, X. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.842983 · Cited by 185
Strategies of fault tolerant operation for three-level PWM inverters
Li, S., & Xu, L. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.876867 · Cited by 147
Fault management of multicell converters
Turpin, C., Baudesson, P., Richardeau, F., Forest, F., & Meynard, T. A. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803196 · Cited by 138
Three-Level Converter Topologies With Switch Breakdown Fault-Tolerance Capability
Ceballos, S., Pou, J., Robles, E., Gabiola, I., Zaragoza, J., Villate, J. L., & Boroyevich, D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917072 · Cited by 133
Self-citationFailures-tolerance and remedial strategies of a PWM multicell inverter
Richardeau, F., Baudesson, P., & Meynard, T. A. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805588 · Cited by 129
Evaluation of Three-Level Rectifiers for Low-Voltage Utility Applications
Teichmann, R., Malinowski, M., & Bernet, S. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843908 · Cited by 95
Efficient Modulation Technique for a Four-Leg Fault-Tolerant Neutral-Point-Clamped Inverter
Ceballos, S., Pou, J., Zaragoza, J., Martín, J. L. M., Robles, E., Gabiola, I., & Ibanez, P. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917098 · Cited by 74
Self-citationModulation Strategies for Fault-Tolerant Operation of H-Bridge Multilevel Inverters
Correa, P., Pacas, M., & Rodríguez, J. (2006) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2006.295709 · Cited by 74
Three-Level Active Neutral-Point-Clamped (ANPC) Converter with Fault Tolerant Ability
Li, J., Huang, A. Q., Bhattacharya, S., & Tan, G. (2009) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802759 · Cited by 55
Fault protection in a multilevel inverter implementation of a static condenser
Sinha, G., Hochgraf, C. G., Lasseter, R. H., Divan, D. M., & Lipo, T. A. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1995.530628 · Cited by 48
Detection and compensation of switch faults in a three level inverter
da Silva, E. R. C., Lima, W. S., de Oliveira, A. S., Jacobina, C. B., & Razik, H. (2006) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2006.1711955 · Cited by 45
Control method of NPC inverter for continuous operation under one phase fault condition
Park, G., Kim, T., Kang, D.-W., & Hyun, D.-S. (2004) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2004.1348780 · Cited by 44
Design of a fault tolerant control system for a NPC multilevel inverter
François, B., & Hautier (2002) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2002.1025937 · Cited by 32
Li, S., & Xu, L. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2001.955479 · Cited by 25
Three-Leg Fault-Tolerant Neutral-Point-Clamped Converter
Ceballos, S., Pou, J., Robles, E., Zaragoza, J., & Martín, J. L. M. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4375124 · Cited by 21
Self-citationSoft-Switching Topology for a Fault-Tolerant Neutral-Point-Clamped Converter
Ceballos, S., Pou, J., Zaragoza, J., Robles, E., Villate, J. L., & Martín, J. L. M. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4375125 · Cited by 16
Self-citationFault-tolerant hybrid four-leg multilevel converter
Ceballos, S., Pou, J., Robles, E., Zaragoza, J., Ibañez, P., & Martín, J. L. M. (2007) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417617 · Cited by 10
Self-citationFault‐tolerant operation of multicell‐inverters with a space phasor modulator
Correa, P., Pacas, M., & Rodríguez, J. (2007) · European Transactions on Electrical Power · doi:10.1002/etep.197 · Cited by 9
Cited by
Sorted by citations
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 867
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 590
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 482
A Review of Multilevel Inverter Topologies in Electric Vehicles: Current Status and Future Trends
Poorfakhraei, A., Narimani, M., & Emadi, A. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3063550 · Cited by 424
“Special modulation schemes for fault-tolerant FC [103], NPC [104]–[106], and MMC [107]”
BackgroundSurvey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodríguez, J., Ceballos, S., & Richardeau, F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 386
Self-citation
Metadata
- Authors
- Ceballos, S., Pou, J., Robles, E., Zaragoza, J., & Martín, J. L.
- Affiliations
- Tecnalia (ES)
- Universitat Politècnica de Catalunya (ES)
- University of the Basque Country (ES)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-08
- Volume
- 57
- Issue
- 8
- Pages
- 2709-2718
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2161930615
- Cited by
- 124
- References
- 26
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 7 · 2021: 19 · 2020: 11 · 2019: 9 · 2018: 5 · 2017: 11 · 2016: 7 · 2015: 7 · 2014: 5 · 2013: 8 · 2012: 9
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- neutral point clamped converter, fault tolerance, switch failure, neutral-point voltage balancing, converter reconfiguration, converter topology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review