Stator Current and Motor Efficiency as Indicators for Different Types of Bearing Faults in Induction Motors
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This paper proposes a new approach to use stator current and efficiency of induction motors as indicators of rolling-bearing faults. After a presentation of the state of the art about condition monitoring of vibration and motor current for the diagnostics of bearings, this paper illustrates the experimental results on four different types of bearing defects: crack in the outer race, hole in the outer race, deformation of the seal, and corrosion. The first and third faults have not been previously considered in the literature, with the latter being analyzed in other research works, even if obtained in a different way. Another novelty introduced by this paper is the analysis of the decrease in efficiency of the motor with a double purpose: as alarm of incipient faults and as evaluation of the extent of energy waste resulting from the lasting of the fault condition before the breakdown of the machine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“An excellent review of the recent condition-monitoring techniques for induction machines, including bearing faults, is reported in [ 4 ].”
BackgroundNeural-network-based motor rolling bearing fault diagnosis
Li, B., Chow, M.-Y., Tipsuwan, Y., & Hung, J. C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873214 · Cited by 797
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Cited by
Ben Ali, J., Fnaiech, N., Saidi, L., Chebel-Morello, B., & Fnaiech, F. (2015) · Applied Acoustics · doi:10.1016/j.apacoust.2014.08.016 · Cited by 768
Prieto, M. D., Cirrincione, G., Espinosa, A. G., Ortega, J. A., & Henao, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2219838 · Cited by 461
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
Leite, V. C. M. N., Borges da Silva, J. G., Veloso, G. F. C., Borges da Silva, L. E., Lambert-Torres, G., Bonaldi, E. L., & de Lacerda de Oliveira, L. E. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345330 · Cited by 274
“Here, artificially produced defects are introduced in the bearing outer race to simulate a localized fault, allowing the evaluation of the applied methodology and a critical comparison with other well-known techniques [13], [15], [22], [33], [43].”
BackgroundMethodResultInfluentialA Probabilistic Fault Detection Approach: Application to Bearing Fault Detection
Zhang, B., Sconyers, C., Byington, C., Patrick, R., Orchard, M. E., & Vachtsevanos, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2058072 · Cited by 269
Frosini, L., Harlisca, C., & Szabo, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361115 · Cited by 264
Self-citationSoualhi, A., Clerc, G., & Razik, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230598 · Cited by 264
Najafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250
AlShorman, O., Irfan, M., Saad, N., Zhen, D., Haider, N., Glowacz, A., & AlShorman, A. (2020) · Shock and Vibration · doi:10.1155/2020/8843759 · Cited by 215
“For nature category, two main faults are considered, including cyclic faults and noncyclic faults [70, 71].”
BackgroundHasan, M. J., Islam, M. M. M., & Kim, J.-M. (2019) · Measurement · doi:10.1016/j.measurement.2019.02.075 · Cited by 203
Wang, J., Peng, Y., & Qiao, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2571258 · Cited by 173
“As listed in Table III, the characteristic frequencies of the bearing inner-race fault in the stator current signal are finner = fP ± frc ± kfBPFI .”
InfluentialGuo, Y., Tan, Z., Chen, H., Li, G., Wang, J., Huang, R., Liu, J., & Ahmad, T. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.075 · Cited by 170
Kang, M., Kim, J., Kim, J.-M., Tan, A. C. C., Kim, E. Y., & Choi, B.-K. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2358494 · Cited by 169
Fault-Tolerant Design Considerations and Control Strategies for Aerospace Drives
Bennett, J. W., Atkinson, G. J., Mecrow, B. C., & Atkinson, D. J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2159356 · Cited by 165
Multisensor Wireless System for Eccentricity and Bearing Fault Detection in Induction Motors
Esfahani, E. T., Wang, S., & Sundararajan, V. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2260865 · Cited by 160
“They used stator current and efficiency of the induction motor for fault detection purposes [27].”
MethodPlastic Bearing Fault Diagnosis Based on a Two-Step Data Mining Approach
He, D., Li, R., & Zhu, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2192894 · Cited by 143
Novel Diagnostic Techniques for Rotating Electrical Machines—A Review
Frosini, L. (2020) · Energies · doi:10.3390/en13195066 · Cited by 67
Self-citation
Metadata
- Authors
- Frosini, L., & Bassi, E.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-01
- Volume
- 57
- Issue
- 1
- Pages
- 244-251
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2114606054
- Cited by
- 254
- References
- 29
- FWCI
- 22.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.