Control of a Single-Phase Cascaded H-Bridge Multilevel Inverter for Grid-Connected Photovoltaic Systems
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper presents a single-phase cascaded H-bridge converter for a grid-connected photovoltaic (PV) application. The multilevel topology consists of several H-bridge cells connected in series, each one connected to a string of PV modules. The adopted control scheme permits the independent control of each dc-link voltage, enabling, in this way, the tracking of the maximum power point for each string of PV panels. Additionally, low-ripple sinusoidal-current waveforms are generated with almost unity power factor. The topology offers other advantages such as the operation at lower switching frequency or lower current ripple compared to standard two-level topologies. Simulation and experimental results are presented for different operating conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Self-citationA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Self-citationGoodwin, G. C., Graebe, S. F., & Salgado, M. E. (2000) · Prentice Hall PTR eBooks · Cited by 1,465
Development of a photovoltaic arraymodel for use in power-electronics simulation studies
Gow, J. A., & Manning, C. D. (1999) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19990116 · Cited by 1,104
Comparative study of maximum power point tracking algorithms
Hohm, D. P., & Ropp, M. E. (2003) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.459 · Cited by 865
Multilevel converters for single-phase grid connected photovoltaic systems-an overview
Calais, M., & Agelidis, V. G. (2002) · IEEE International Symposium on Industrial Electronics. Proceedings. ISIE'98 (Cat. No.98TH8357) · doi:10.1109/isie.1998.707781 · Cited by 380
Alonso, O., Sanchis, P., Gubia, E., & Marroyo, L. (2003) · IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03. · doi:10.1109/pesc.2003.1218146 · Cited by 197
A passivity-based multilevel active rectifier with adaptive compensation for traction applications
Cecati, C., Dell’Aquila, A., Liserre, M., & Monopoli, V. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816552 · Cited by 124
Cited by
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Self-citationAbu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Self-citationMultilevel Inverter Topologies With Reduced Device Count: A Review
Gupta, K. K., Ranjan, A., Bhatnagar, P., Sahu, L. K., & Jain, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2405012 · Cited by 1,193
Li, W., Gu, Y., Luo, H., Cui, W., He, X., & Xia, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2399278 · Cited by 671
A New Multilevel Converter Topology With Reduced Number of Power Electronic Components
Ebrahimi, J., Babaei, E., & Gharehpetian, G. B. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151813 · Cited by 525
Packed U Cells Multilevel Converter Topology: Theoretical Study and Experimental Validation
Ounejjar, Y., Al-Haddad, K., & Grégoire, L.-A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2050412 · Cited by 467
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2264540 · Cited by 449
Single-Phase Seven-Level Grid-Connected Inverter for Photovoltaic System
Rahim, N. A., Chaniago, K., & Selvaraj, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064278 · Cited by 438
Chavarria, J., Biel, D., Guinjoan, F., Meza, C., & Negroni, J. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2186108 · Cited by 391
Bana, P. R., Panda, K. P., Naayagi, R. T., Siano, P., & Panda, G. (2019) · IEEE Access · doi:10.1109/access.2019.2913447 · Cited by 361
Li, Y., Wang, Y., & Li, B. Q. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2476699 · Cited by 238
“During the past few decades, the CHB converter has been widely studied in the application of photovoltaic generation [10], battery energy storage system [11], cascade STATCOM [12]–[14], variable-speed drive [15], and SST or PET [16]–[18].”
BackgroundA New Multilevel Inverter Topology With Reduce Switch Count
Siddique, M. D., Mekhilef, S., Shah, N. M., Sarwar, A., Iqbal, A., & Memon, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2914430 · Cited by 222
“The topology has been compared with [14] and results presented claims to require lesser installation space and cost because of the reduced number of switching devices, switching and conduction losses and total standing voltage.”
ResultLiu, L., Li, H., Xue, Y., & Liu, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2333004 · Cited by 212
“1 can be replaced by Quasi-Z-Source network or be removed according to system requirement [7], [29], [30], [32].”
BackgroundSingle-Phase Single-Stage Transformer less Grid-Connected PV System
Alajmi, B. N., Ahmed, K. H., Adam, G. P., & Williams, B. W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2228280 · Cited by 207
Multilevel Medium-Frequency Link Inverter for Utility Scale Photovoltaic Integration
Essakiappan, S., Krishnamoorthy, H. S., Enjeti, P., Balog, R. S., & Ahmed, S. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2350978 · Cited by 161
New hybrid structure for multilevel inverter with fewer number of components for high‐voltage levels
Alishah, R. S., Nazarpour, D., Hosseini, S. H., & Sabahi, M. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0156 · Cited by 160
Cascaded multilevel SST medium voltage converter for solar applications
Foureaux, N. C., Filho, B. J. C., & Brito, J. A. S. (2015) · 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7167874 · Cited by 13
Metadata
- Authors
- Villanueva, E., Correa, P., Rodriguez, J., & Pacas, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 4399-4406
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2136109242
- Cited by
- 795
- References
- 9
- FWCI
- 24.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.