A Survey on Neutral-Point-Clamped Inverters
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Neutral-point-clamped (NPC) inverters are the most widely used topology of multilevel inverters in high-power applications (several megawatts). This paper presents in a very simple way the basic operation and the most used modulation and control techniques developed to date. Special attention is paid to the loss distribution in semiconductors, and an active NPC inverter is presented to overcome this problem. This paper discusses the main fields of application and presents some technological problems such as capacitor balance and losses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Self-citationA New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Self-citationPatel, H. S., & Hoft, R. G. (1973) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1973.349908 · Cited by 1,221
A new approach to enhance power quality for medium voltage AC drives
Hammond, P. W. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567113 · Cited by 857
The Active NPC Converter and Its Loss-Balancing Control
Bruckner, T., Bernet, S., & Guldner, H. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.847586 · Cited by 731
Self-citationRecent developments of high power converters for industry and traction applications
Bernet, S. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.892825 · Cited by 458
Self-citationActive-neutral-point-clamped (ANPC) multilevel converter technology
Barbosa, P., Steimer, P., Steinke, J., Winkelnkemper, M., & Celanovic, N. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219713 · Cited by 379
Self-citationA Flexible Selective Harmonic Mitigation Technique to Meet Grid Codes in Three-Level PWM Converters
Franquelo, L. G., Napoles, J., Guisado, R. C. P., Leon, J. I., & Aguirre, M. A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907045 · Cited by 264
Loss balancing in three-level voltage source inverters applying active NPC switches
Bruckner, T., & Bemet, S. (2002) · 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230) · doi:10.1109/pesc.2001.954272 · Cited by 256
Voltage Balancing Control of Diode-Clamped Multilevel Rectifier/Inverter Systems
Pan, Z., Peng, F. Z., Corzine, K. A., Stefanovic, V. R., Leuthen, J. M., & Gataric, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.857473 · Cited by 213
Saeedifard, M., Iravani, R., & Pou, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.905967 · Cited by 203
Predictive Control Algorithm Technique for Multilevel Asymmetric Cascaded H-Bridge Inverters
Perez, M. A., Cortes, P., & Rodriguez, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2006948 · Cited by 167
Self-citationA Comprehensive Study of a Hybrid Modulation Technique for the Neutral-Point-Clamped Converter
Zaragoza, J., Pou, J., Ceballos, S., Robles, E., Ibanez, P., & Villate, J. L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005132 · Cited by 163
Control of Three-Level PWM Converter Applied to Variable-Speed-Type Turbines
Malinowski, M., Styński, S., Kolomyjski, W., & Kaźmierkowski, M. P. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.927245 · Cited by 140
Videt, A., Moigne, P. L., Idir, N., Baudesson, P., & Cimetiere, X. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907001 · Cited by 129
Feedforward Loss Control of Three-Level Active NPC Converters
Bruckner, T., Bernet, S., & Steimer, P. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.908164 · Cited by 125
Self-citationHoltz, J., & Οικονόμου, Ν. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.895767 · Cited by 124
Busquets‐Monge, S., Ortega, J. D., Bordonau, J., Beristáin, J., & Rocabert, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918646 · Cited by 107
How to Select the System Voltage of MV Drives—A Comparison of Semiconductor Expenses
Sayago, J., Bruckner, T., & Bernet, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924032 · Cited by 82
Self-citationThree-level active NPC converter: PWM strategies and loss distribution
Floricău, D., Floricau, E., & Gateau, G. (2008) · doi:10.1109/iecon.2008.4758494 · Cited by 71
Very High Power IGCT PEBB technology
Steimer, P., Odegard, B., Apeldoorn, O., Bernet, S., & Bruckner, T. (2005) · PESC record · doi:10.1109/pesc.2005.1581594 · Cited by 61
Self-citationThree-Level Active Neutral-Point-Clamped (ANPC) Converter with Fault Tolerant Ability
Li, J., Huang, A. Q., Bhattacharya, S., & Tan, G. (2009) · 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802759 · Cited by 54
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Power Electronics Converters for Wind Turbine Systems
Blaabjerg, F., Liserre, M., & Ma, K. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2181290 · Cited by 918
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“Moreover, these converters require significant modifications to increase their operating voltage and output voltage levels, which is not cost-effective [10]–[14].”
Babaei, E., Laali, S., & Bayat, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336601 · Cited by 523
Metadata
- Authors
- Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-07
- Volume
- 57
- Issue
- 7
- Pages
- 2219-2230
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2116444921
- Cited by
- 1,813
- References
- 23
- FWCI
- 44.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.