Energy Management System of Fuel-Cell-Battery Hybrid Tramway
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper describes the configuration, modeling, and control of a fuel cell (FC)-battery-powered hybrid system for the Metro Centro tramway in Seville, Spain. The proposed hybrid system presents a polymer electrolyte membrane FC as the primary energy source and a nickel-metal hydride cell battery as the secondary energy source, which supplements the output of the FC during tramway acceleration or whenever else needed and cruise and for energy recovery during braking. The tramway presents a traction system which is composed of four traction induction motor drives. The hybrid system also supplies the power for the auxiliary services. The power conditioning system is composed of two converters: 1) a boost-type unidirectional dc/dc converter for the FC and 2) a boost-type bidirectional dc/dc converter for the battery. The energy management system (EMS) of the hybrid tramway determines the reference signals for the electric motor drives, FC, and power converters in order to regulate accurately the power from the two electrical sources. EMS also determines the reference signal for energy dissipation in braking chopper when required during regenerative braking. In this paper, the proposed hybrid system is evaluated for the real driving cycle of the tramway. The results demonstrate the hybrid system capability to meet appropriate driving cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The state of the art of electric, hybrid, and fuel cell vehicles
Chan, C. C. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.892489 · Cited by 1,987
Emadi, A., Lee, Y. J., & Rajashekara, K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922768 · Cited by 1,461 · cited 2×
“2034173 auxiliary power device, presents the following advantages [2],”
BackgroundPulse‐Width Modulated DC‐DC Power Converters
Kazimierczuk, M. K. (2008) · Wiley eBooks · doi:10.1002/9780470694640 · Cited by 1,109
Energy Storage Systems for Automotive Applications
Lukic, S. M., Cao, J., Bansal, R. C., Rodriguez, F., & Emadi, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918390 · Cited by 1,025
(2003) · Focus on Catalysts · doi:10.1016/s1351-4180(03)00256-3 · Cited by 761
The Power Electronics Handbook
(2018) · CRC Press eBooks · doi:10.1201/9781420037067 · Cited by 534
Ultracapacitor-Based Auxiliary Energy System for an Electric Vehicle: Implementation and Evaluation
Ortuzar, M., Moreno, J., & Dixon, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894713 · Cited by 529
Energy Management Power Converters in Hybrid Electric and Fuel Cell Vehicles
Lai, J.-S., & Nelson, D. J. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.890122 · Cited by 318 · cited 2×
“A boost-type bidirectional dc/dc converter [16]–[18] is used as power converter for battery energy management.”
MethodEnergy management strategy based on fuzzy logic for a fuel cell hybrid bus
Gao, D., Jin, Z., & Lu, Q. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.06.083 · Cited by 270
Optimal fuzzy power control and management of fuel cell/battery hybrid vehicles
Li, C.-Y., & Liu, G.-P. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.03.007 · Cited by 255
Fuel cell high-power applications
Sethakul, P., Rael, S., Davat, B., & Thounthong, P. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.930365 · Cited by 208
Multiphase Bidirectional Flyback Converter Topology for Hybrid Electric Vehicles
Bhattacharya, T., Giri, V. S., Mathew, K., & Umanand, L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004661 · Cited by 177
Adaptive supervisory control strategy of a fuel cell/battery-powered city bus
Xu, L., Li, J., Hua, J., Li, X., & Ouyang, M. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.04.074 · Cited by 136
Power management strategy for vehicular-applied hybrid fuel cell/battery power system
Li, X., Xu, L., Hua, J., Lin, X., Li, J., & Ouyang, M. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.01.092 · Cited by 130
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
“Examples of unidirectional dc–dc conversion in railway systems include an FC-battery hybrid tramway that utilizes a boost converter to regulate the dc traction bus voltage (∼700–800 V) [222] and [223].”
BackgroundDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Hybrid electric vehicles and their challenges: A review
Hannan, M. A., Azidin, F. A., & Mohamed, A. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.08.097 · Cited by 766
Njoya Motapon, S., Dessaint, L.-A., & Al-Haddad, K. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2257152 · Cited by 548
Metadata
- Authors
- Garcia, P., Fernandez, L. M., Garcia, C. A., & Jurado, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-12
- Volume
- 57
- Issue
- 12
- Pages
- 4013-4023
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2107343234
- Cited by
- 296
- References
- 14
- FWCI
- 24.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.