Quasi-Z-Source-Based Isolated DC/DC Converters for Distributed Power Generation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper presents new step-up dc/dc converter topologies intended for distributed power generation systems. The topologies contain a voltage-fed quasi-Z-source inverter with continuous input current on the primary side, a single-phase isolation transformer, and a voltage doubler rectifier (VDR). To increase the power density of the converter, a three-phase auxiliary ac link (a three-phase inverter and a three-phase isolation transformer) and a three-phase VDR are proposed to be implemented. This paper describes the operation principles of the proposed topologies and analyzes the theoretical and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, F. Z. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808920 · Cited by 3,228
Anderson, J., & Peng, F. Z. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4592360 · Cited by 1,174
High-Efficiency Isolated Boost DC–DC Converter for High-Power Low-Voltage Fuel-Cell Applications
Nymand, M., & Andersen, M. A. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036024 · Cited by 312
Harfman Todorovic, M., Palma, L., & Enjeti, P. N. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911200 · Cited by 263
A Ripple-Mitigating and Energy-Efficient Fuel Cell Power-Conditioning System
Mazumder, S. K., Burra, R. K., & Acharya, K. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900598 · Cited by 242
Low Cost Fuel Cell Converter System for Residential Power Generation
Wang, J., Peng, F. Z., Anderson, J., Joseph, A., & Buffenbarger, R. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833455 · Cited by 240
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Self-citationImpedance-Source Networks for Electric Power Conversion Part I: A Topological Review
Siwakoti, Y. P., Peng, F. Z., Blaabjerg, F., Loh, P. C., & Town, G. E. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2313746 · Cited by 702
Modeling and Control of Quasi-Z-Source Inverter for Distributed Generation Applications
Li, Y., Jiang, S., Cintron-Rivera, J. G., & Peng, F. Z. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2213551 · Cited by 382
Raghavendra, K. V. G., Zeb, K., Muthusamy, A., Krishna, T. N. V., Kumar, S. V. S. V. P., Kim, D.-H., Kim, M.-S., Cho, H.-G., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics9010031 · Cited by 269
Metadata
- Authors
- Vinnikov, D., & Roasto, I.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-01
- Volume
- 58
- Issue
- 1
- Pages
- 192-201
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2078108796
- Cited by
- 398
- References
- 6
- FWCI
- 19.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.