Robust Controller for DFIGs of Grid-Connected Wind Turbines
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper proposes a new robust controller in a stationary reference frame for doubly fed induction generators (DFIGs) of grid-connected wind turbines. Initially, a DFIG dynamic model is derived from the voltage and flux equations in$\alpha\beta$coordinates, where uncertainties and disturbances intrinsic to the system are accounted for as perturbation terms are added to the nominal model. Then, a controller design procedure that guarantees the DFIG stability under uncertainties and disturbances at the grid side is presented in detail. It is demonstrated that a very fast dynamic behavior can be obtained with the proposed controller, which improves the transient response of the grid-connected DFIG, particularly under conditions of unbalanced voltage dips resulting from asymmetrical network faults. In order to conform with the fault ride-through capability requirements, this paper proposes a new reference strategy, which is divided into normal and fault operation modes. Experimental results are given to support the theoretical analysis and to illustrate the performance of the grid-connected DFIG with the proposed controller.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018 · cited 1×
“The DFIG with PI controllers and its performance under normal operation conditions has been discussed in a number of publications [7]–[11].”
BackgroundGautam, D., Vittal, V., & Harbour, T. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2021234 · Cited by 680
Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator
Morren, J., & de Haan, S. W. H. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889615 · Cited by 538 · cited 1×
“In addition, due to the magnetic coupling between stator and rotor windings, high voltages are induced in the rotor terminals, and consequently, high currents flow through the converters [21].”
BackgroundRotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults
Lima, F. K. A., Luna, Á., Rodríguez, P., Watanabe, E. H., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2025651 · Cited by 415
Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips
López, J., Gubía, E., Olea, E., Ruiz, J., & Marroyo, L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2028447 · Cited by 358 · cited 1×
“When the rotor-side voltage or current reaches the power converter limit, the control of the DFIG is lost and protected to avoid thermal breakdown of the converter [22]–[24].”
BackgroundCoordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance
Xu, L. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921157 · Cited by 310 · cited 1×
“An LVRT simulation study of a 2-MW wind power DFIG has been presented in [30], and a control and operation strategy for DFIG systems during a network voltage unbalance has been presented in [31].”
MethodFPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005244 · Cited by 245 · cited 1×
“A fault detection method for DFIG systems was investigated in [35].”
MethodDoubly Fed Induction Generator Model-Based Sensor Fault Detection and Control Loop Reconfiguration
Rothenhagen, K., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013683 · Cited by 157 · cited 1×
“including disturbed grid conditions, the control gains must be carefully tuned [42], [43].”
BackgroundCurrent Sensor Fault Detection, Isolation, and Reconfiguration for Doubly Fed Induction Generators
Rothenhagen, K., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017562 · Cited by 152
Cited by
Overview of Control Systems for the Operation of DFIGs in Wind Energy Applications
Cardenas, R., Pena, R., Alepuz, S., & Asher, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2243372 · Cited by 670
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
LVRT Capability of DFIG-Based WECS Under Asymmetrical Grid Fault Condition
Geng, H., Liu, C., & Yang, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2226417 · Cited by 231
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- da Costa, J. P., Pinheiro, H., Degner, T., & Arnold, G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-09
- Volume
- 58
- Issue
- 9
- Pages
- 4023-4038
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2171982351
- Cited by
- 182
- References
- 9
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.