The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Stress-Detection System Based on Physiological Signals and Fuzzy Logic
Open accessAbstract
A stress-detection system is proposed based on physiological signals. Concretely, galvanic skin response (GSR) and heart rate (HR) are proposed to provide information on the state of mind of an individual, due to their nonintrusiveness and noninvasiveness. Furthermore, specific psychological experiments were designed to induce properly stress on individuals in order to acquire a database for training, validating, and testing the proposed system. Such system is based on fuzzy logic, and it described the behavior of an individual under stressing stimuli in terms of HR and GSR. The stress-detection accuracy obtained is 99.5% by acquiring HR and GSR during a period of 10 s, and what is more, rates over 90% of success are achieved by decreasing that acquisition period to 3–5 s. Finally, this paper comes up with a proposal that an accurate stress detection only requires two physiological signals, namely, HR and GSR, and the fact that the proposed stress-detection system is suitable for real-time applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Cited by
Stress and anxiety detection using facial cues from videos
Giannakakis, G., Pediaditis, M., Manousos, D., Kazantzaki, E., Chiarugi, F., Simos, P. G., Marias, K., & Tsiknakis, M. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.06.020 · Cited by 342
Arza, A., Garzón-Rey, J. M., Lázaro, J., Gil, E., Lopez-Anton, R., de la Camara, C., Laguna, P., Bailon, R., & Aguiló, J. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1879-z · Cited by 148
Can smartphones detect stress-related changes in the behaviour of individuals?
Bauer, G., & Lukowicz, P. (2012) · 2012 IEEE International Conference on Pervasive Computing and Communications Workshops · doi:10.1109/percomw.2012.6197525 · Cited by 111
Mentis, A.-F. A., Lee, D., & Roussos, P. (2024) · Molecular Psychiatry · doi:10.1038/s41380-023-02047-6 · Cited by 75
Villarejo, M., Zapirain, B., & Zorrilla, A. (2013) · Sensors · doi:10.3390/s130506141 · Cited by 20
Metadata
- Authors
- de Santos Sierra, A., Sanchez Avila, C., Guerra Casanova, J., & Bailador del Pozo, G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-10
- Volume
- 58
- Issue
- 10
- Pages
- 4857-4865
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2098708941
- Cited by
- 224
- References
- 1
- FWCI
- 15.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Stress-Detection System Based on Physiological Signals and Fuzzy Logic. https://app.cochat.ai/papers/10.1109/tie.2010.2103538
- The paper
- de Santos Sierra, A., Sanchez Avila, C., Guerra Casanova, J., & Bailador del Pozo, G. (2011). A Stress-Detection System Based on Physiological Signals and Fuzzy Logic. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2010.2103538
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.