The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current Errors
Abstract
Three-phase inverters are currently utilized in an enormous variety of industrial applications, including variable-speed ac drives. However, due to their complexity and exposure to several stresses, they are prone to suffer critical failures. Accordingly, this paper presents a novel diagnostic algorithm that allows the real-time detection and localization of multiple power switch open-circuit faults in inverter-fed ac motor drives. The proposed method is quite simple and just requires the measured motor phase currents and their corresponding reference signals, already available from the main control system, therefore avoiding the use of additional sensors and hardware. Several experimental results using a vector-controlled permanent-magnet synchronous motor drive are presented, showing the diagnostic algorithm effectiveness, its relatively fast detection time, and its robustness against false alarms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because the open-circuit fault causes an erroneous value of the output voltage, an increase in current harmonics and torque pulsations, its diagnosis is of research interest so that the PM machine can safely operate in critical systems application [254].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [254]
Citations
Cites
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A. T., Mawby, P., Xiang, D., Ran, L., & Tavner, P. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,058
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
Ribeiro, R. L. A., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Zidani, F., Diallo, D., Benbouzid, M., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · Conference record · doi:10.1109/ias.1997.629048 · Cited by 304
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Śleszyński, W., NIEZNAŃSKI, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
Cited by
Sorted by citations
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Self-citationRiera‐Guasp, M., Daviu, J. A. A., & Capolino, G. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 580
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 472
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Metadata
- Authors
- Estima, J. O., & Marques Cardoso, A. J.
- Affiliations
- Instituto de Telecomunicações (PT)
- ORCID
- Estima, Jorge O.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-08
- Volume
- 60
- Issue
- 8
- Pages
- 3496-3505
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2032232674
- Cited by
- 377
- References
- 33
- Citations by year
- 2026: 4 · 2025: 12 · 2024: 25 · 2023: 27 · 2022: 27 · 2021: 35 · 2020: 37 · 2019: 36 · 2018: 26 · 2017: 37 · 2016: 35 · 2015: 33 · 2014: 26 · 2013: 14
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- open-circuit fault diagnosis, multiple fault detection, fault location, three-phase inverter, sensorless fault diagnosis, permanent magnet synchronous motor, vector control, real-time fault detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review