The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique
Abstract
A small-scale wind energy conversion system can track the maximum power point (MPP) based on a linear relationship betweenVdc2andIdc. Unlike conventional MPP tracking (MPPT) methods using a lookup table, an advanced technique is proposed based on this relationship as a variant of the perturb and observe (P&O) method. It not only has the advantages of the conventional P&O method but also has a faster tracking speed and better performance. This paper theoretically analyzes the possible power coefficient drop when using a linear relationship for MPPT and establishes that the turbine design can ensure that the possible power coefficient drop is small. The simulation results show that the analysis is precise. The validity and performance of the proposed MPPT method are confirmed by both simulation and experimentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Power electronics converters, applications and design
Robinson, F. V. P. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(97)87859-7 · Cited by 5,075
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Optimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002
A Variable Step Size INC MPPT Method for PV Systems
Liu, F., Duan, S., Liu, F., Liu, B., & Kang, Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920550 · Cited by 1,313
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Design of a maximum power tracking system for wind-energy-conversion applications
Koutroulis, E., & Kalaitzakis, K. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.870658 · Cited by 921
Tan, K., & Islam, S. M. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827038 · Cited by 722
Highly Efficient Single-Phase Transformerless Inverters for Grid-Connected Photovoltaic Systems
Araujo, S. V., Zacharias, P., & Mallwitz, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037654 · Cited by 636
Vasquez, J. C., Guerrero, J. M., Luna, A., Rodriguez, P., & Teodorescu, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027921 · Cited by 629
Cited by
Wei, C., Zhang, Z., Qiao, W., & Qu, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2420792 · Cited by 178
Metadata
- Authors
- Xia, Y., Ahmed, K. H., & Williams, B. W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-03
- Volume
- 60
- Issue
- 3
- Pages
- 1122-1132
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2144051042
- Cited by
- 256
- References
- 25
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique. https://app.cochat.ai/papers/10.1109/tie.2012.2206332
- The paper
- Xia, Y., Ahmed, K. H., & Williams, B. W. (2013). Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2206332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.