The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Detection and Diagnosis of Faults in Induction Motor Using an Improved Artificial Ant Clustering Technique
Abstract
The presence of electrical and mechanical faults in the induction motors (IMs) can be detected by analysis of the stator current spectrum. However, when an IM is fed by a frequency converter, the spectral analysis of stator current signal becomes difficult. For this reason, the monitoring must depend on multiple signatures in order to reduce the effect of harmonic disturbance on the motor-phase current. The aim of this paper is the description of a new approach for fault detection and diagnosis of IMs using signal-based method. It is based on signal processing and an unsupervised classification technique called the artificial ant clustering. The proposed approach is tested on a squirrel-cage IM of 5.5 kW in order to detect broken rotor bars and bearing failure at different load levels. The experimental results prove the efficiency of our approach compared with supervised classification methods in condition monitoring of electrical machines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ANFIS: adaptive-network-based fuzzy inference system
Jang, J.-S. R. (1993) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.256541 · Cited by 16,254
THE USE OF MULTIPLE MEASUREMENTS IN TAXONOMIC PROBLEMS
FISHER, R. A. (1936) · Annals of Eugenics · doi:10.1111/j.1469-1809.1936.tb02137.x · Cited by 15,227
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_4 · Cited by 6,594
Survey of Clustering Algorithms
Xu, R., & WunschII, D. (2005) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2005.845141 · Cited by 6,197
Robust Model-Based Fault Diagnosis for Dynamic Systems
Chen, J., & Patton, R. J. (1999) · The International Series on Asian Studies in Computer and Information Science · doi:10.1007/978-1-4615-5149-2 · Cited by 4,262
Fuzzy Model Identification Based on Cluster Estimation
Chiu, S. L. (1994) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/ifs-1994-2306 · Cited by 2,782
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Introduction to multi-layer feed-forward neural networks
Svozil, D., Kvasnicka, V., & Pospichal, J. (1997) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(97)00061-0 · Cited by 1,600
Fault detection and diagnosis in engineering systems
Thomas, P. (2002) · Control Engineering Practice · doi:10.1016/s0967-0661(02)00064-3 · Cited by 1,171
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
AI techniques in induction machines diagnosis including the speed ripple effect
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.658729 · Cited by 442
Condition Monitoring of Rotating Electrical Machines
Tavner, P., Ran, L., Penman, J., & Sedding, H. (2008) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo056e · Cited by 331
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Riera-Guasp, M., Antonino-Daviu, J. A., Pineda-Sanchez, M., Puche-Panadero, R., & Perez-Cruz, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004378 · Cited by 267
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266
Frosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Nejjari, H., & Benbouzid, M. E. H. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845047 · Cited by 247
Ordaz-Moreno, A., de Jesus Romero-Troncoso, R., Vite-Frias, J. A., Rivera-Gillen, J. R., & Garcia-Perez, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918613 · Cited by 227
Seera, M., Lim, C. P., Ishak, D., & Singh, H. (2012) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2011.2178443 · Cited by 185
Detection of Induction Motor Faults: A Comparison of Stator Current, Vibration and Acoustic Methods
Li, W., & Mechefske, C. K. (2006) · Journal of Vibration and Control · doi:10.1177/1077546306062097 · Cited by 151
Strangas, E. G., Aviyente, S., & Zaidi, S. S. H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007529 · Cited by 148
Pons-Llinares, J., Daviu, J. A. A., Riera‐Guasp, M., Pineda‐Sanchez, M., & Climente-Alarcón, V. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081955 · Cited by 142
Önel, İ. Y. İ. Y., & Benbouzid, M. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.918535 · Cited by 141
Tsang, C.-H., & Kwong, S. (2006) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2005.1600609 · Cited by 134
Kia, S. H., Henao, H., & Capolino, G. (2007) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/07ias.2007.292 · Cited by 123
Pineda‐Sanchez, M., Riera‐Guasp, M., Daviu, J. A. A., Roger-Folch, J., Pérez‐Cruz, J., & Puche‐Panadero, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026211 · Cited by 111
On the Use of Slot Harmonics as a Potential Indicator of Rotor Bar Breakage in the Induction Machine
Khezzar, A., Kaikaa, M. Y., Oumaamar, M. E. K., Boucherma, M., & Razik, H. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030819 · Cited by 82
Self-citationThe detection of interturn stator faults in doubly-fed induction generators
Douglas, H., Pillay, P., & Barendse, P. (2005) · doi:10.1109/ias.2005.1518493 · Cited by 79
A method to detect broken bars in induction machine using pattern recognition techniques
Ondel, O., Boutleux, E., & Clerc, G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876071 · Cited by 70
Self-citationInduction machine fault diagnosis using an external radial flux sensor
Romary, R., Corton, R., Thailly, D., & Brudny, J. F. (2005) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2005079 · Cited by 56
An acoustic diagnostic technique for use with electric machine insulation
Lee, Y.-S., Nelson, J. K., Scarton, H. A., Teng, D., & Azizi-Ghannad, S. (1994) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.368645 · Cited by 52
Stator-Interlaminar-Fault Detection Using an External-Flux-Density Sensor
Romary, R., Jelassi, S., & Brudny, J. F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029525 · Cited by 51
Fault detection and diagnosis of induction motors based on hidden Markov model
Soualhi, A., Clerc, G., Razik, H., et al. (2012) · doi:10.1109/icelmach.2012.6350108 · Cited by 38
Self-citationAsynchronous motor cage fault detection through electromagnetic torque measurement
Thollon, F., Grellet, G., & Jammal, A. (1993) · European Transactions on Electrical Power · doi:10.1002/etep.4450030509 · Cited by 38
Study of an induction motor working under stator winding inter-turn short circuit condition
Melero, M. G., Cabanas, M. F., Rojas, C. H., Orcajo, G. A., Cano, J. M., & Solares, J. (2003) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2003.1234546 · Cited by 37
Intelligent Diagnosis of Broken Bars in Induction Motors Based on New Features in Vibration Spectrum
Sadoughi, A., Ebrahimi, M., Moallem, M., et al. (2007) · IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2007.4393079 · Cited by 31
Detection of induction motor faults by an improved artificial ant clustering
Soualhi, A., Clerc, G., Razik, H., & Ondel, O. (2011) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2011.6119866 · Cited by 16
Self-citationFilho, E. R., Riehl, R. R., & Avolio, E. (2002) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.1994.333157 · Cited by 13
Cited by
A review on the application of deep learning in system health management
Khan, S., & Yairi, T. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.11.024 · Cited by 1,133
Gao, Z., Cecati, C., & Ding, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2419013 · Cited by 776
Bearing Health Monitoring Based on Hilbert–Huang Transform, Support Vector Machine, and Regression
Soualhi, A., Medjaher, K., & Zerhouni, N. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2330494 · Cited by 665
Self-citationGangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Metadata
- Authors
- Soualhi, A., Clerc, G., & Razik, H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-09
- Volume
- 60
- Issue
- 9
- Pages
- 4053-4062
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2063492964
- Cited by
- 264
- References
- 40
- FWCI
- 27.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.