Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Current-Demodulated Signals
The DOI matches its Crossref record.
Abstract
Bearing faults account for a large portion of all faults in wind turbine generators (WTGs). Current-based bearing fault diagnosis techniques have great economic benefits and are potential to be adopted by the wind energy industry. This paper models the modulation effects of bearing faults on the stator currents of a direct-drive wind turbine equipped with a permanent-magnet synchronous generator (PMSG) operating with a variable shaft rotating frequency. Based on the analysis, a method consisting of appropriate current frequency and amplitude demodulation algorithms and a 1P-invariant power spectrum density algorithm is proposed for bearing fault diagnosis of variable-speed direct-drive wind turbines using only one-phase stator current measurements, where 1P frequency stands for the shaft rotating frequency of a wind turbine. Experimental results on a direct-drive wind turbine equipped with a PMSG operating in a wind tunnel are provided to verify the proposed fault diagnosis method. The proposed method is demonstrated to have advantages over the method of directly using stator current measurements for WTG bearing fault diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
“Recent development of current-based spectrum signature analysis for fault diagnosis can be found in [156] and [157].”
BackgroundThe state of the art of wind energy conversion systems and technologies: A review
Cheng, M., & Zhu, Y. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.08.037 · Cited by 600
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Liu, Z., & Zhang, L. (2020) · Measurement · doi:10.1016/j.measurement.2019.107002 · Cited by 535
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533
Self-citationQiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422394 · Cited by 407
Self-citationA review of stochastic resonance in rotating machine fault detection
Lu, S., He, Q., & Wang, J. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.032 · Cited by 382
Badihi, H., Zhang, Y., Jiang, B., Pillay, P., & Rakheja, S. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3171691 · Cited by 319
Wang, X.-B., Yang, Z.-X., & Yan, X.-A. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2787686 · Cited by 296
From Corrective to Predictive Maintenance—A Review of Maintenance Approaches for the Power Industry
Molęda, M., Małysiak-Mrozek, B., Ding, W., Sunderam, V., & Mrozek, D. (2023) · Sensors · doi:10.3390/s23135970 · Cited by 288
Leite, V. C. M. N., Borges da Silva, J. G., Veloso, G. F. C., Borges da Silva, L. E., Lambert-Torres, G., Bonaldi, E. L., & de Lacerda de Oliveira, L. E. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345330 · Cited by 274
Wang, J., Peng, Y., & Qiao, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2571258 · Cited by 173
“Moreover, generator current signals are already measured and used by wind turbine control systems [28]; no additional sensor or data acquisition hardware is required.”
Self-citationDe Kooning, J. D. M., Stockman, K., De Maeyer, J., Jarquin-Laguna, A., & Vandevelde, L. (2021) · Processes · doi:10.3390/pr9122224 · Cited by 57
“Moreover, several techniques are described in the literature for monitoring the condition of wind turbine bearings based on electrical signals [95,96], acoustic emissions [97] and vibration measurements [98].”
BackgroundLu, L., He, Y., Wang, T., Shi, T., & Ruan, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2936228 · Cited by 35
Metadata
- Authors
- Gong, X., & Qiao, W.
- Venue
- Industrial Electronics, IEEE Transactions on
- Published
- 2013-04
- Volume
- 60
- Issue
- 8
- Pages
- 3419-3428
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2013548240
- Cited by
- 195
- References
- 0
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.