The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Generalized Fault-Tolerant Control Strategy for Five-Phase PM Motor Drives Considering Star, Pentagon, and Pentacle Connections of Stator Windings
Abstract
In this paper, a generalized optimal fault-tolerant control (FTC) technique is proposed for open-circuit faults in five-phase permanent-magnet (PM) machine drives. The proposed FTC technique considers pentagon and pentacle connections of stator windings in addition to conventional star connection. Open-circuit faults in stator windings of the machine as well as switches of the inverter are analyzed. The optimization objective is to produce ripple-free electromagnetic torque with minimum ohmic losses under open-circuit fault conditions. This is achieved by a simple closed-form equation to calculate reference optimal currents in all cases where a lookup table is utilized to represent the effect of fault type. The proposed FTC technique is easily extended to PM machines with higher number of phases. Experimental results for a five-phase PM machine drive are provided to demonstrate the proposed FTC strategy. In addition to single and double faults, which are analyzed for five-phase machine with star connection, triple-phase faults are also considered in pentagon and pentacle connections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376 · cited 1×
“the machines can still continue operations using the remaining healthy phases without additional hardware [10], [16]–[24].”
BackgroundFault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Wang, T., Xu, H., Han, J., Elbouchikhi, E., & Benbouzid, M. E. H. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2393373 · Cited by 273
Metadata
- Authors
- Mohammadpour, A., Sadeghi, S., & Parsa, L.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-01
- Volume
- 61
- Issue
- 1
- Pages
- 63-75
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2040592137
- Cited by
- 210
- References
- 3
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Generalized Fault-Tolerant Control Strategy for Five-Phase PM Motor Drives Considering Star, Pentagon, and Pentacle Connections of Stator Windings. https://app.cochat.ai/papers/10.1109/tie.2013.2247011
- The paper
- Mohammadpour, A., Sadeghi, S., & Parsa, L. (2014). A Generalized Fault-Tolerant Control Strategy for Five-Phase PM Motor Drives Considering Star, Pentagon, and Pentacle Connections of Stator Windings. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2013.2247011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.