Modulation Methods for Neutral-Point-Clamped Wind Power Converter Achieving Loss and Thermal Redistribution Under Low-Voltage Ride-Through
Open accessThe DOI matches its Crossref record.
Abstract
The three-level neutral-point (NP)-clamped (3L-NPC) converter is a promising multilevel topology in the application of megawatt wind power generation systems. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology. This paper investigates the loss and thermal performances of a 10-MW 3L-NPC wind power inverter undergoing low-voltage ride-through (LVRT) operation. A series of new space vector modulation methods is then proposed to relocate the thermal loading among the power switching devices. It is concluded that, with the proposed modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also, the control ability of the dc-bus NP potential, which is one of the crucial considerations for the 3L-NPC converter, is even more improved by the proposed modulation methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Self-citationJunction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
Self-citationElectric Vehicle Charging Station Using a Neutral Point Clamped Converter With Bipolar DC Bus
Rivera, S., Wu, B., Kouro, S., Yaramasu, V., & Wang, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348937 · Cited by 305
Yang, Y., Enjeti, P., Blaabjerg, F., & Wang, H. (2015) · IEEE Industry Applications Magazine · doi:10.1109/mias.2014.2345837 · Cited by 262
Self-citationReliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2325891 · Cited by 258
Self-citationComplete Loss and Thermal Model of Power Semiconductors Including Device Rating Information
Ma, K., Bahman, A. S., Beczkowski, S., & Blaabjerg, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2352341 · Cited by 199
Self-citationHeat Management in Power Converters: From State of the Art to Future Ultrahigh Efficiency Systems
Laloya, E., Lucia, O., Sarnago, H., & Burdio, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513433 · Cited by 188
Review of Power Semiconductor Device Reliability for Power Converters
School of Electrical Engineering, C. U., & Wang, B. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00011 · Cited by 174
Rana, R. A., Patel, S. A., Muthusamy, A., Lee, C. W., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics8111329 · Cited by 102
“The explanation as to why the frequency converter is connected to the series with a diode; means that all diodes have the same rated voltage and may block a correct voltage level [18].”
BackgroundDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Metadata
- Authors
- Ma, K., & Blaabjerg, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-02
- Volume
- 61
- Issue
- 2
- Pages
- 835-845
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1965287768
- Cited by
- 172
- References
- 0
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.