The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Distributed Control Strategy for Coordination of an Autonomous LVDC Microgrid Based on Power-Line Signaling
Open accessAbstract
In a microgrid (MG), an energy management control is essential in order to handle the variety of prime movers, which may include different types of renewable energy sources (RESs) and energy storage systems (ESSs). Specifically, the recharging process of the secondary battery, i.e., the most prominent ESS, should be done in a specific manner to preserve its lifetime, the common MG bus voltage must be kept within the bounds, and the energy offered by RES should be utilized as efficiently as possible. This paper proposes a method for coordination of an autonomous low-voltage direct-current (LVDC) MG that consists of a number of sources using power-line signaling (PLS), which is a distributed control strategy in which the units inject sinusoidal signals of specific frequency into the common bus in order to communicate with each other. The control structure that allows the application of this method is revealed, and the optimal range of operating PLS frequencies is specified. In order to achieve a zero steady-state error of injected signals in the common bus, primary control of batteries has been extended with dedicated proportional-resonant controllers that are switched on only during injection period. Finally, a method for coordination among the units using the PLS concept was developed and experimentally tested, confirming its applicability for autonomous LVDC MGs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citation
Cited by
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Self-citationDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Self-citationState of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Review on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Self-citationControl Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454
Metadata
- Authors
- Dragicevic, T., Guerrero, J. M., & Vasquez, J. C.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-07
- Volume
- 61
- Issue
- 7
- Pages
- 3313-3326
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2100665834
- Cited by
- 178
- References
- 1
- FWCI
- 27.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Distributed Control Strategy for Coordination of an Autonomous LVDC Microgrid Based on Power-Line Signaling. https://app.cochat.ai/papers/10.1109/tie.2013.2282597
- The paper
- Dragicevic, T., Guerrero, J. M., & Vasquez, J. C. (2014). A Distributed Control Strategy for Coordination of an Autonomous LVDC Microgrid Based on Power-Line Signaling. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2013.2282597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.