Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper proposes an effective test bed for a 380-V dc distribution system using isolated power converters. The proposed test-bed system is composed of a grid-interactive ac-dc converter for regulating the dc-bus voltage, a bidirectional converter for the battery power interface, a renewable energy simulator, dc home appliances modified from conventional ac components, a dc distribution panel board, and its monitoring system. This paper discusses three isolated power converters, i.e., a bidirectional ac-dc converter, a bidirectional dc-dc converter, and a unidirectional dc-dc converter for the effective power interface of a dc bus. These isolated power converters are designed using a dual-active-bridge converter and the resonant topologies of CLLC and LLC. The proposed test-bed system was implemented using a 5-kW bidirectional ac-dc prototype converter, a 3-kW bidirectional dc-dc prototype converter, and a 3-kW unidirectional dc-dc prototype converter. Finally, the performance of the test-bed system has been verified using practical experiments of load variations and bidirectional power flow, employing the prototype converters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
High-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305 · cited 2×
“ers, isolated boost and full-bridge converters, isolated boost and phase-shifted full-bridge converters [15]–[17], dual active bridge (DAB) converters [18]–[23], [32], [33], CLLC resonant converters [12]–[14], and current-fed isolated dc–dc converters”
Background
Cited by
He, P., & Khaligh, A. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2016.2630927 · Cited by 501
“The CLLC and dual active bridge (DAB) converters are commonly used as the DC-DC stages for bidirectional EV chargers, due to their advantages in terms of high power density, high efficiency, buck/boost capability, and controllable bidirectional power transfer [13]-[15].”
BackgroundA 300-kHz 6.6-kW SiC Bidirectional LLC Onboard Charger
Li, H., Zhang, Z., Wang, S., Tang, J., Ren, X., & Chen, Q. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2910048 · Cited by 237
“On the other hand, in order to address the problem of LLC bidirectional operation, a CLLLC converter is derived by adding an LC pair on the secondary side of the LLC converter [11]–[13].”
Zhao, B., Song, Q., Li, J., Liu, W., Liu, G., & Zhao, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2483543 · Cited by 175
“alize power conversion through simple magnetic transformer as widely used in ac distribution [7]–[8]; it especially needs power electronics technology.”
BackgroundA SiC Bidirectional LLC On-Board Charger
Li, H., Wang, S., Zhang, Z., Tang, J., Ren, X., & Chen, Q. (2019) · 2019 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2019.8722324 · Cited by 32
“However, there is an extra LC pair [10].”
Background
Metadata
- Authors
- Ryu, M.-H., Kim, H.-S., Baek, J.-W., Kim, H.-G., & Jung, J.-H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-07
- Volume
- 62
- Issue
- 7
- Pages
- 4525-4536
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1970900775
- Cited by
- 158
- References
- 4
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.