PV Power System With Multi-Mode Operation and Low-Voltage Ride-Through Capability
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A multi-mode operation for the three-phase photovoltaic (PV) power system with low-voltage ride-through (LVRT) capability is proposed. With the proposed multi-mode control strategy, the active power from the PV arrays can be continuously extracted by the interleaved boost converter during LVRT, whereas the maximum power point tracking operation can be quickly achieved after the grid fault clearance. In addition, the multi-channel boost converter with interleaved operation can increase power conversion efficiency while decreasing the input current ripple. On the other hand, the current amplitude limitation control of the three-phase inverter can provide maximum reactive power under rated current amplitude during the voltage sag period and output the demanded reactive/rated current ratio to meet different LVRT codes. A three-phase 5-kVA prototype PV converter is built and tested to verify the performance of the proposed multi-mode operation strategy and the LVRT capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, Z., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2236580 · Cited by 230
Cited by
Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review
Panigrahi, R., Mishra, S. K., Srivastava, S. C., Srivastava, A. K., & Schulz, N. N. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2979789 · Cited by 214
“The amount of reactive power to be fed during the LVRT operation is decided by the grid voltage level and inverter VA capabilities [125].”
BackgroundPower control flexibilities for grid‐connected multi‐functional photovoltaic inverters
Yang, Y., Blaabjerg, F., Wang, H., & Simões, M. G. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0133 · Cited by 182
Delta Power Control Strategy for Multistring Grid-Connected PV Inverters
Sangwongwanich, A., Yang, Y., Blaabjerg, F., & Sera, D. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2681044 · Cited by 175
A review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Haghighat, M., Niroomand, M., Dehghani Tafti, H., D. Townsend, C., & Fernando, T. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000845 · Cited by 30
Metadata
- Authors
- Tang, C.-Y., Chen, Y.-T., & Chen, Y.-M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-12
- Volume
- 62
- Issue
- 12
- Pages
- 7524-7533
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2003511652
- Cited by
- 174
- References
- 1
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.