Cited by 122Multilevel Inverters and ConvertersAdvanced DC-DC ConvertersPower Quality and Harmonics

A Novel Multilevel Multioutput Bidirectional Active Buck PFC Rectifier

Vahedi, Hani, Al-Haddad, Kamal·2016·IEEE Transactions on Industrial Electronics

Abstract

This paper presents a new family of buck type power factor corrector rectifiers that operates in continuous-conduction mode (CCM) and generates a multilevel voltage waveform at the input. Due to CCM operation, commonly used ac-side capacitive filter and dc-side inductive filter are removed from the proposed modified packed U-cell rectifier structure. Dual dc output terminals are provided to have a five-level voltage waveform at the input points of the rectifier where it is supplied by a grid via a line inductor. Producing different voltage levels reduces the voltage harmonics which affects the grid current harmonic contents directly. Low switching frequency of the proposed rectifier is a distinguished characteristic among other buck type rectifiers that reduces switching losses and any high switching frequency related issues, significantly. The proposed transformerless, reduced filter, and multilevel rectifier topology has been investigated experimentally to validate the good dynamic performance in generating and regulating dual 125-V dc outputs terminals as telecommunication boards feeders or industrial battery chargers under various situation including change in the loads and change in the main grid voltage amplitude.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2016.2555279

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [2][2] IEEE, "IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems," in IEEE Std 519-2014 (Revision of IEEE Std 519-1992) , ed, 2014, pp. 1-29. -

Cited by

Sorted by citations

Authors
Vahedi, H., & Al-Haddad, K.
Affiliations
École de Technologie Supérieure (CA)
Venue
IEEE Transactions on Industrial Electronics
Published
2016-09
Volume
63
Issue
9
Pages
5442-5450
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2342190714
Cited by
122
References
28
Citations by year
2026: 6 · 2025: 14 · 2024: 6 · 2023: 14 · 2022: 9 · 2021: 14 · 2020: 9 · 2019: 15 · 2018: 13 · 2017: 13 · 2016: 9
FWCI
7.69
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Industrial Electronics (publishedVersion)
  • Espace ÉTS (ETS) (acceptedVersion)
Funders
  • Canadian Research Chair in Electric Energy Conversion and Power Electronics
  • Natural Sciences and Engineering Research Council of Canada
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
Keywords
power factor correction, multilevel rectifier, bidirectional rectifier, continuous conduction mode, grid current harmonics, low switching frequency, telecommunications power supply, battery charger

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review