Current-Aided Order Tracking of Vibration Signals for Bearing Fault Diagnosis of Direct-Drive Wind Turbines
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Vibration monitoring is one of the most popular, effective, and reliable methods for bearing fault diagnosis. A key issue in the vibration monitoring for the bearings used in variable-speed wind turbines is the elimination of the effect of the turbine shaft speed fluctuation in the vibration signals measured under varying-rotating-speed conditions. This paper proposes a new current-aided vibration order tracking method for bearing fault diagnosis of variable-speed direct-drive (i.e., no gearbox) wind turbines. The method explores a new simple and effective approach to acquire the reference signal from a current signal measured from the stator of the generator for vibration order tracking. First, the instantaneous fundamental frequency of the current signal is estimated in the time-frequency domain to obtain the shaft rotating frequency. Then, the shaft phase-time relationship is established. With this information, the envelope of the synchronously recorded vibration signal is subsequently resampled at the equal-phase-increment time points. Finally, bearing fault diagnosis is performed by observing the peaks at bearing characteristic frequencies in the power spectrum of the resampled vibration envelope signal. The proposed method is validated by successful diagnosis of different bearing faults in a direct-drive wind turbine under varying-speed conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rolling element bearing diagnostics—A tutorial
Randall, R. B., & Antoni, J. (2011) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2010.07.017 · Cited by 2,744 · cited 1×
“, accelerometers) attached to the casings of bearings with a constant sampling time interval, and are further analyzed using appropriate signal processing techniques to extract the bearing fault information [8].”
Real-Time Implementation of Fault-Tolerant Control Systems With Performance Optimization
Yin, S., Luo, H., & Ding, S. X. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273477 · Cited by 644 · cited 1×
“Unlike the data-driven process monitoring methods which construct the process models according to the historical data [3]–[5], the methods of bearing fault diagnosis usually intend to extract the fault features from the data currently acquired from appropriate sensors.”
ANALYSIS OF COMPUTED ORDER TRACKING
Fyfe, K. R., & Munck, E. D. S. (1997) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1996.0056 · Cited by 598 · cited 1×
“Order tracking is an effective technique to solve the spectrum smearing problem caused by speed variation so that the conventional spectrum analysis methods can be employed afterwards [11].”
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568 · cited 1×
“In the proposed method, the current signal is not used for fault signature extraction for bearing fault diagnosis of induction motors [22]–[26] or direct-drive wind turbines [27], [28], but a resource to provide the information of the shaft speed for the order tracking of the vibration signal.”
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533 · cited 1×
“2571258 generator, gearbox, yaw, pitch, and other rotating parts of wind turbines [2].”
Self-citationMotor Bearing Fault Diagnosis Using Trace Ratio Linear Discriminant Analysis
Jin, X., Zhao, M., Chow, T. W. S., & Pecht, M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273471 · Cited by 423 · cited 1×
“Vibration monitoring has been widely recognized as one of the most popular, effective, and reliable methods for bearing condition monitoring and fault diagnosis [6], [7].”
Immovilli, F., Bellini, A., Rubini, R., & Tassoni, C. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049623 · Cited by 382
Improved instantaneous frequency estimation using an adaptive short-time Fourier transform
Kwok, H. K., & Jones, D. L. (2000) · IEEE Transactions on Signal Processing · doi:10.1109/78.869059 · Cited by 293
Zhao, Y., Wei, C., Zhang, Z., & Qiao, W. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2280572 · Cited by 274 · cited 1×
“generators [13].”
Self-citationData-Driven Process Monitoring Based on Modified Orthogonal Projections to Latent Structures
Yin, S., Wang, G., & Gao, H. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2481318 · Cited by 258 · cited 1×
“Unlike the data-driven process monitoring methods which construct the process models according to the historical data [3]–[5], the methods of bearing fault diagnosis usually intend to extract the fault features from the data currently acquired from appropriate sensors.”
Cited by
Liu, Z., & Zhang, L. (2020) · Measurement · doi:10.1016/j.measurement.2019.107002 · Cited by 535
Electric Locomotive Bearing Fault Diagnosis Using a Novel Convolutional Deep Belief Network
Shao, H., Jiang, H., Zhang, H., & Liang, T. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2745473 · Cited by 488
Badihi, H., Zhang, Y., Jiang, B., Pillay, P., & Rakheja, S. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3171691 · Cited by 319
A Review on Vibration-Based Condition Monitoring of Rotating Machinery
Tiboni, M., Remino, C., Bussola, R., & Amici, C. (2022) · Applied Sciences · doi:10.3390/app12030972 · Cited by 314
Pan, J., Zi, Y., Chen, J., Zhou, Z., & Wang, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2767540 · Cited by 294
Improvement of kurtosis-guided-grams via Gini index for bearing fault feature identification
Miao, Y., Zhao, M., & Lin, J. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa8a57 · Cited by 282
Lu, S., Yan, R., Liu, Y., & Wang, Q. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2902806 · Cited by 271
Wang, X., Lu, S., Huang, W., Wang, Q., Zhang, S., & Xia, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3051668 · Cited by 65
A novel method based on self-sensing motor drive system for misalignment detection
Yao, Y., Li, Y., & Yin, Q. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.030 · Cited by 42
Metadata
- Authors
- Wang, J., Peng, Y., & Qiao, W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-10
- Volume
- 63
- Issue
- 10
- Pages
- 6336-6346
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2404620877
- Cited by
- 173
- References
- 29
- FWCI
- 16.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.