The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Small-Signal Analysis of the Microgrid Secondary Control Considering a Communication Time Delay
Open accessAbstract
This paper presents a small-signal analysis of an islanded microgrid composed of two or more voltage-source inverters connected in parallel. The primary control of each inverter is integrated through an internal current and voltage loops using proportional resonant compensators, a virtual impedance, and an external power controller based on frequency and voltage droops. The frequency restoration function is implemented at the secondary control level, which executes a consensus algorithm that consists of a load-frequency control and a single time delay communication network. The consensus network consists of a time-invariant directed graph and the output power of each inverter is the information shared among the units, which is affected by the time delay. The proposed small-signal model is validated through simulation results and experimental results. A root locus analysis is presented that shows the behavior of the system considering control parameters and time delay variation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Problems in Networks of Agents With Switching Topology and Time-Delays
Olfati-Saber, R., & Murray, R. M. (2004) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2004.834113 · Cited by 12,788 · cited 2×
“er. Thus, another network will be used for implementing the frequency restoration that being a data link network. This new network can be presented in several topologies. A strongly connected example [14] is shown in Fig. 4, where only three inverters are considered. The data link network in Fig. 4 is a directed graph…”
BackgroundMethodConsensus and Cooperation in Networked Multi-Agent Systems
Olfati-Saber, R., Fax, J. A., & Murray, R. M. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.887293 · Cited by 10,522
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citation
Cited by
Han, Y., Zhang, K., Li, H., Coelho, E. A. A., & Guerrero, J. M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2761438 · Cited by 501
Self-citationDistributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
On the Secondary Control Architectures of AC Microgrids: An Overview
Khayat, Y., Shafiee, Q., Heydari, R., Naderi, M., Dragicevic, T., Simpson-Porco, J. W., Dorfler, F., Fathi, M., Blaabjerg, F., Guerrero, J. M., et al. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2951694 · Cited by 385
Self-citationNew Perspectives on Droop Control in AC Microgrid
Sun, Y., Hou, X., Yang, J., Han, H., Su, M., & Guerrero, J. M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677328 · Cited by 292
Self-citation
Metadata
- Authors
- Coelho, E. A. A., Wu, D., Guerrero, J. M., Vasquez, J. C., Dragicevic, T., Stefanovic, C., & Popovski, P.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-10
- Volume
- 63
- Issue
- 10
- Pages
- 6257-6269
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2433797745
- Cited by
- 227
- References
- 3
- FWCI
- 22.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.