Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 385

The DOI matches its Crossref record; 154 of the 154 references it cites were found in a registry or an index.

On the Secondary Control Architectures of AC Microgrids: An Overview

Open access
Khayat, Yousef, Shafiee, Qobad, Heydari, Rasool, Naderi, Mobin, Dragicevic, Tomislav, Simpson-Porco, John W., Dorfler, Florian, Fathi, Mohammad, Blaabjerg, Frede, Guerrero, Josep M., Bevrani, Hassan·2020·IEEE Transactions on Power Electronics

Abstract

Communication infrastructure (CI) in microgrids (MGs) allows for the application of different control architectures for the secondary control (SC) layer. The use of new SC architectures involving CI is motivated by the need to increase MG resilience and handle the intermittent nature of distributed generation units. The structure of SC is classified into three main categories, including centralized SC (CSC) with a CI, distributed SC (DISC) generally with a low-data-rate CI, and decentralized SC (DESC) with communication-free infrastructure. To meet the MGs' operational constraints and optimize performance, control and communication must be utilized simultaneously in different control layers. In this survey, we review and classify all types of SC policies from CI-based methods to communication-free policies, including CSC, averaging-based DISC, consensus-based DISC methods, containment pinning consensus, event-triggered DISC, washout-filter-based DESC, and state-estimation-based DESC. Each structure is scrutinized from the viewpoint of the relevant literature. Challenges such as clock drifts, cyber-security threats, and the advantage of event-triggered approaches are presented. Fully decentralized approaches based on state-estimation and observation methods are also addressed. Although these approaches eliminate the need of any CI for the voltage and frequency restoration, during black start process or other functionalities related to the tertiary layer, a CI is required. Power hardware-in-the-loop experimental tests are carried out to compare the merits and applicability of different SC structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2019.2951694

Cites

154 of 154 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 154 references

Metadata

Authors
Khayat, Y., Shafiee, Q., Heydari, R., Naderi, M., Dragicevic, T., Simpson-Porco, J. W., Dorfler, F., Fathi, M., Blaabjerg, F., Guerrero, J. M., & Bevrani, H.
Venue
IEEE Transactions on Power Electronics
Published
2020-06
Volume
35
Issue
6
Pages
6482-6500
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2983436474
Cited by
385
References
154
FWCI
22.76
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the Secondary Control Architectures of AC Microgrids: An Overview. https://app.cochat.ai/papers/10.1109/tpel.2019.2951694
The paper
Khayat, Y., Shafiee, Q., Heydari, R., Naderi, M., Dragicevic, T., Simpson-Porco, J. W., Dorfler, F., Fathi, M., Blaabjerg, F., Guerrero, J. M., & Bevrani, H. (2020). On the Secondary Control Architectures of AC Microgrids: An Overview. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2019.2951694

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.