Flexible Power Regulation and Current-Limited Control of the Grid-Connected Inverter Under Unbalanced Grid Voltage Faults
Abstract
The grid-connected inverters may experience excessive current stress in case of unbalanced grid voltage fault ride through (FRT), which significantly affects the reliability of the power supply system. In order to solve the problem, the inherent mechanisms of the excessive current phenomenon with the conventional FRT solutions are discussed. The quantitative analysis of three-phase current peak values is conducted and a novel current-limited control strategy is proposed to achieve the flexible active and reactive power regulation and successful FRT in a safe current operation area with the aim of improving the system reliability under grid faults. Finally, the simulation and experiments of traditional and proposed FRT solutions are carried out. The results verify the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Cited by
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546
Liu, W., Tarasiuk, T., Su, C.-L., Gorniak, M., Savaghebi, M., Vasquez, J. C., & Guerrero, J. M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2885722 · Cited by 17
“The lowest voltage can be calculated by several methods [30], [31].”
Self-citation
Metadata
- Authors
- Guo, X., Liu, W., & Lu, Z.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 7425-7432
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2589051533
- Cited by
- 201
- References
- 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.