The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Abstract
With an increasing number of distributed energy resources integrated into the power system, inverters need to take on the corresponding responsibility for the security and stability of the system. Virtual synchronous generators (VSGs) are proposed to mimic dynamic characteristics of traditional rotational synchronous generators (RSGs) to compensate for the loss of inertia and reserve capacity. Similar to RSGs, VSGs will experience transient angle instability under certain conditions, which likely threatens the system security. In this paper, transient angle stability of a VSG is investigated by Lyapunov's direct method. The deteriorative effect of reactive power control loop on transient angle stability is first analyzed and then voltage variation is incorporated into an approximate Lyapunov's direct method. In this method, the inverter internal voltage is treated as a parameter rather than a state variable. Moreover, the influence of different parameters on transient angle stability is studied. Finally, an enhanced control strategy is presented to improve the transient angle stability by adjusting the reference power. Numerical simulation results are presented to validate the effectiveness of the proposed method and the enhanced control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
He, J., & Li, Y. W. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168592 · Cited by 759
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Control of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700
Equivalence of Virtual Synchronous Machines and Frequency-Droops for Converter-Based MicroGrids
D’Arco, S., & Suul, J. A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2288000 · Cited by 674
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Transient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Rokrok, E., Qoria, T., Bruyere, A., Francois, B., & Guillaud, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3107959 · Cited by 311
Metadata
- Authors
- Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-07
- Volume
- 10
- Issue
- 4
- Pages
- 4648-4661
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2952105605
- Cited by
- 546
- References
- 25
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method. https://app.cochat.ai/papers/10.1109/tsg.2018.2866122
- The paper
- Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019). Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2018.2866122
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.