The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Integration of DC Microgrids as Virtual Synchronous Machines Into the AC Grid
Abstract
A smart and autonomous integration concept for dc microgrids into the legacy ac grid is proposed based on the virtual synchronous machine (VSM) concept. It utilizes a dc-ac converter as a universal VSM-based interface (VSMBI) between the ac grid and various distributed energy resources (DER) connected on the dc side. The control strategy of it includes: 1) a frequency regulation improved from previous VSM works, which is suitable for the microgrid integration; 2) an improved dual droop control between the ac frequency and the dc side energy storages; 3) a power system stabilizer to enhance the system stability. Under this concept, the VSMBI integrates the DERs, loads and energy storages in the dc microgrid into a VSM. The VSMBI and the dc microgrid together will respond to short-term and long-term requirements of the grid frequency regulation, and achieve autonomous power management for the ac grid and the dc microgrid. It is therefore an important step forward in supporting high DER penetration. The concept, its design and small-signal analysis are presented in this paper. Its effectiveness and functions are verified by simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Metadata
- Authors
- Chen, D., Xu, Y., & Huang, A. Q.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 7455-7466
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2591574082
- Cited by
- 193
- References
- 1
- FWCI
- 14.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of DC Microgrids as Virtual Synchronous Machines Into the AC Grid. https://app.cochat.ai/papers/10.1109/tie.2017.2674621
- The paper
- Chen, D., Xu, Y., & Huang, A. Q. (2017). Integration of DC Microgrids as Virtual Synchronous Machines Into the AC Grid. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2674621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.