A Novel High Step-Up DC–DC Converter With Continuous Input Current Integrating Coupled Inductor for Renewable Energy Applications
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In this paper, a nonisolated dc-dc converter with high voltage gain is presented. Three diodes, three capacitors, an inductor, and a coupled inductor are employed in the presented converter. Since the inductor is connected to the input, the low input current ripple is achieved, which is important for tracking maximum power point of photovoltaic panels. The voltage stress across switch S is clamped by diode D 1 and capacitor C1. Therefore, a main switch with low on-resistance RDS (on) can be employed to reduce the conduction loss. Besides, the main switch is turned on under zero current. This reduces the switching loss. The steady-state analysis of the proposed converter is discussed in this paper. Finally, the proposed converter prototype circuit is implemented to justify the validity of the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Transformerless DC–DC Converters With High Step-Up Voltage Gain
Yang, L.-S., Liang, T.-J., & Chen, J.-F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2022512 · Cited by 808 · cited 1×
“Ideally, conventional boost converter can achieve high conversion ratio with high duty cycle, but in practice, because of low conversion efficiency, reverse-recovery, and electromagnetic interference problems, the high voltage gain cannot be obtained [9], [10], [28].”
BackgroundHigh Step-Up Converter With Coupled-Inductor
Wai, R.-J., & Duan, R.-Y. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.854023 · Cited by 611
Boost Converter With Coupled Inductors and Buck–Boost Type of Active Clamp
Wu, T.-F., Lai, Y.-S., Hung, J.-C., & Chen, Y.-M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.903925 · Cited by 425
Ajami, A., Ardi, H., & Farakhor, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360495 · Cited by 406 · cited 4×
“Coupled inductor based converters can achieve high voltage gain by adjusting the turn ratios [17], [18].”
BackgroundMethodSelf-citationNovel High Step-Up DC–DC Converter for Fuel Cell Energy Conversion System
Changchien, S.-K., Liang, T., Chen, J.-F., & Yang, L.-S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026364 · Cited by 369 · cited 1×
“Many coupled inductor based converters with different voltage clamps have been proposed recently [19]–[25].”
BackgroundNovel High Step-Up DC–DC Converter With Coupled-Inductor and Switched-Capacitor Techniques
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151828 · Cited by 326 · cited 1×
“There have been some techniques applied such as switched capacitors [11]–[13] and voltage lift [14]–[16] to obtain high voltage gain.”
MethodTseng, K., & Huang, C.-C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2261036 · Cited by 319 · cited 1×
“In order to solve this problem, coupled inductor based interleaved converters have been proposed [22]–[23].”
BackgroundNovel High Step-Up DC–DC Converter for Distributed Generation System
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2107721 · Cited by 295 · cited 7×
“As shown in this figure, although the RMS value of the switch current in the proposed converter is more than the converter proposed in [26], the efficiency of the proposed converter is more than the converter in [26].”
BackgroundMethodInfluentialA Modified SEPIC Converter With High Static Gain for Renewable Applications
Gules, R., dos Santos, W. M., dos Reis, F. A., Romaneli, E. F. R., & Badin, A. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2296053 · Cited by 280
Analysis and Implementation of a Non-Isolated Bidirectional DC-DC Converter with High Voltage Gain
Ardi, H., Ajami, A., Kardan, F., & Nikpour, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2552139 · Cited by 244 · cited 5×
“According to [1], [18], and [28], by considering a certain ripple value, the sizes of capacitor CO is calculated using (39).”
BackgroundMethodSelf-citationNovel High Step-Up DC–DC Converter With Coupled-Inductor and Voltage-Doubler Circuits
Yang, L.-S., Liang, T.-J., Lee, H.-C., & Chen, J.-F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098360 · Cited by 242
A Switched-Capacitor DC–DC Converter With High Voltage Gain and Reduced Component Rating and Count
Qian, W., Cao, D., Cintron-Rivera, J. G., Gebben, M., Wey, D., & Peng, F. Z. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2199731 · Cited by 233
Non‐isolated multi‐input–single‐output DC/DC converter for photovoltaic power generation systems
Banaei, M. R., Ardi, H., Alizadeh, R., & Farakhor, A. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0977 · Cited by 233 · cited 1×
“However, the ignorance of shadow effect in this case cannot be obtained [4], [5].”
BackgroundSelf-citationNovel Isolated High-Step-Up DC–DC Converter With Voltage Lift
Liang, T.-J., Lee, J.-H., Chen, S.-M., Chen, J.-F., & Yang, L.-S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2177789 · Cited by 223
A Boost Converter With Capacitor Multiplier and Coupled Inductor for AC Module Applications
Chen, S.-M., Liang, T.-J., Yang, L.-S., & Chen, J.-F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2169642 · Cited by 190 · cited 4×
“Voltage gain versus duty ratio of the proposed converter, the converters in [3], [7], [17], [23], [26], and [29].”
BackgroundInfluentialLee, J.-H., Liang, T.-J., & Chen, J.-F. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278517 · Cited by 166 · cited 1×
“However, the ignorance of shadow effect in this case cannot be obtained [4], [5].”
BackgroundHigh Step-Up DC/DC Topology and MPPT Algorithm for Use With a Thermoelectric Generator
Laird, I., & Lu, D. D. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2219393 · Cited by 163 · cited 7×
“As can be seen, the voltage gain of the proposed converter is higher than converters proposed in [3], [17], and [23].”
BackgroundMethodInfluentialPower Electronics and Energy Conversion Systems: Fundamentals and Hard‐switching Converters
Ioinovici, A. (2013) · Wiley eBooks · doi:10.1002/9781118443040 · Cited by 150
Non‐isolated bidirectional DC–DC converter analysis and implementation
Ardi, H., Ahrabi, R. R., & Ravadanegh, S. N. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0898 · Cited by 103
Self-citation
Cited by
A novel high‐conversion‐ratio bidirectional three‐phase DC–DC converter
Wang, F., Wang, Y., Zhang, F., & Teng, C. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8782 · Cited by 14
Metadata
- Authors
- Ardi, H., Ajami, A., & Sabahi, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-02
- Volume
- 65
- Issue
- 2
- Pages
- 1306-1315
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2741173782
- Cited by
- 248
- References
- 21
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.