Validation of Faster Joint Control Strategy for Battery- and Supercapacitor-Based Energy Storage System
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Energy storage system (ESS) is generally used to manage the intermittency of the renewable energy sources (RESs). The proper control strategy is needed to effectively maintain the power balance between the RESs, load demand, and ESS. The conventional control strategy for the hybrid energy storage system (HESS) uses the high-/low-pass filter method for system net power decomposition and the ESS power dispatch. In this paper, a new joint control strategy is proposed for photovoltaic-based dc grid system, with battery and supercapacitor (SC) as a HESS. The new joint control strategy utilizes the uncompensated power from the battery system to increase the performance of the overall HESS. The advantages of the proposed control strategy over the conventional control strategy are faster dc-link voltage restoration and effective power sharing between the battery and the SC. The detailed stability analysis of the proposed control strategy is also presented. The effectiveness of the proposed control strategy over the conventional control strategy is validated with the short-term and long-term experimental studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nehrir, M. H., Wang, C., Strunz, K., Aki, H., Ramakumar, R., Bing, J., Miao, Z., & Salameh, Z. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2157540 · Cited by 928
Zhou, H., Bhattacharya, T., Tran, D., Siew, T. S. T., & Khambadkone, A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095040 · Cited by 704
Fundamentals of battery dynamics
Jossen, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.10.041 · Cited by 510 · cited 1×
“the rapid change in the rate of charge/discharge current may affect the battery lifetime [24].”
BackgroundA Model Predictive Control System for a Hybrid Battery-Ultracapacitor Power Source
Hredzak, B., Agelidis, V. G., & Jang, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262003 · Cited by 449 · cited 1×
“In [13], MPC is implemented to control the HESS currents and to maintain the state-of-charge (SOC) limits of the battery and the SC to predefined limits.”
MethodLi, W., Joos, G., & Belanger, J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037103 · Cited by 448 · cited 1×
“PV is preferred in terms of sustainability and reliability, but its generation and stability are easily affected by intermittent operating conditions such as change in irradiance, temperature, humidity, and partial shadings effects [2], [3].”
BackgroundDesign and Analysis of Novel Control Strategy for Battery and Supercapacitor Storage System
Kollimalla, S. K., Mishra, M. K., & Narasamma, N. L. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2336896 · Cited by 398 · cited 1×
“The rate of charge/discharge of SC is faster compared to the battery so the controller parameters are basically tuned based on the SC power stage [30].”
BackgroundSelf-citationSchaltz, E., Khaligh, A., & Rasmussen, P. O. (2009) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2009.2027909 · Cited by 357 · cited 5×
“Unlike the conventional control strategy [25]–[27], the power required to balance the overall power flow in the dc link during load and generation”
BackgroundMethodResultInfluentialBattery/Supercapacitors Combination in Uninterruptible Power Supply (UPS)
Lahyani, A., Venet, P., Guermazi, A., & Troudi, A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210736 · Cited by 355 · cited 1×
“HESS sizing method for EV application is presented in [19], and for uninterruptable power supply application in [20].”
MethodA Hybrid Fuel Cell Power System
Jin, K., Ruan, X., Yang, M., & Xu, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008336 · Cited by 331 · cited 1×
“PV is preferred in terms of sustainability and reliability, but its generation and stability are easily affected by intermittent operating conditions such as change in irradiance, temperature, humidity, and partial shadings effects [2], [3].”
BackgroundDevelopment of hybrid battery–supercapacitor energy storage for remote area renewable energy systems
Ma, T., Yang, H., & Lu, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.12.008 · Cited by 324 · cited 1×
“[21] presented the application of HESS in remote area RESs.”
Method
Cited by
Hybrid energy storage system for microgrids applications: A review
Hajiaghasi, S., Salemnia, A., & Hamzeh, M. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.12.017 · Cited by 585
Grid Integration Challenges and Solution Strategies for Solar PV Systems: A Review
Shafiullah, M., Ahmed, S. D., & Al-Sulaiman, F. A. (2022) · IEEE Access · doi:10.1109/access.2022.3174555 · Cited by 473
Babu, T. S., Vasudevan, K. R., Ramachandaramurthy, V. K., Sani, S. B., Chemud, S., & Lajim, R. M. (2020) · IEEE Access · doi:10.1109/access.2020.3015919 · Cited by 354
“Another control technique named FJC is proposed in [26] for control of HESS in DC microgrids.”
BackgroundMethodKhalid, M. (2019) · Energies · doi:10.3390/en12234559 · Cited by 183
Reinforcement Learning Based Energy Management Algorithm for Smart Energy Buildings
Kim, S., & Lim, H. (2018) · Energies · doi:10.3390/en11082010 · Cited by 169
“This hybrid ESS can take both the advantages of battery (high energy density and low cost per kWh) and super-capacitor (quick charging/discharging and extended lifetime) [23].”
BackgroundPeng, J., Wang, R., Liao, H., Zhou, Y., Li, H., Wu, Y., & Huang, Z. (2019) · Energies · doi:10.3390/en12030440 · Cited by 25
Metadata
- Authors
- Manandhar, U., Tummuru, N. R., Kollimalla, S. K., Ukil, A., Beng, G. H., & Chaudhari, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-04
- Volume
- 65
- Issue
- 4
- Pages
- 3286-3295
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2750974078
- Cited by
- 227
- References
- 28
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.