Validation of Faster Joint Control Strategy for Battery- and Supercapacitor-Based Energy Storage System
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Energy storage system (ESS) is generally used to manage the intermittency of the renewable energy sources (RESs). The proper control strategy is needed to effectively maintain the power balance between the RESs, load demand, and ESS. The conventional control strategy for the hybrid energy storage system (HESS) uses the high-/low-pass filter method for system net power decomposition and the ESS power dispatch. In this paper, a new joint control strategy is proposed for photovoltaic-based dc grid system, with battery and supercapacitor (SC) as a HESS. The new joint control strategy utilizes the uncompensated power from the battery system to increase the performance of the overall HESS. The advantages of the proposed control strategy over the conventional control strategy are faster dc-link voltage restoration and effective power sharing between the battery and the SC. The detailed stability analysis of the proposed control strategy is also presented. The effectiveness of the proposed control strategy over the conventional control strategy is validated with the short-term and long-term experimental studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nehrir, M. H., Wang, C., Strunz, K., Aki, H., Ramakumar, R., Bing, J., Miao, Z., & Salameh, Z. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2157540 · Cited by 928
Zhou, H., Bhattacharya, T., Tran, D., Siew, T. S. T., & Khambadkone, A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095040 · Cited by 704
Fundamentals of battery dynamics
Jossen, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.10.041 · Cited by 510 · cited 1×
“the rapid change in the rate of charge/discharge current may affect the battery lifetime [24].”
BackgroundA Model Predictive Control System for a Hybrid Battery-Ultracapacitor Power Source
Hredzak, B., Agelidis, V. G., & Jang, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262003 · Cited by 449 · cited 1×
“In [13], MPC is implemented to control the HESS currents and to maintain the state-of-charge (SOC) limits of the battery and the SC to predefined limits.”
MethodLi, W., Joos, G., & Belanger, J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037103 · Cited by 448 · cited 1×
“PV is preferred in terms of sustainability and reliability, but its generation and stability are easily affected by intermittent operating conditions such as change in irradiance, temperature, humidity, and partial shadings effects [2], [3].”
BackgroundDesign and Analysis of Novel Control Strategy for Battery and Supercapacitor Storage System
Kollimalla, S. K., Mishra, M. K., & Narasamma, N. L. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2336896 · Cited by 398 · cited 1×
“The rate of charge/discharge of SC is faster compared to the battery so the controller parameters are basically tuned based on the SC power stage [30].”
BackgroundSelf-citationSchaltz, E., Khaligh, A., & Rasmussen, P. O. (2009) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2009.2027909 · Cited by 357 · cited 5×
“Unlike the conventional control strategy [25]–[27], the power required to balance the overall power flow in the dc link during load and generation”
BackgroundMethodResultInfluentialBattery/Supercapacitors Combination in Uninterruptible Power Supply (UPS)
Lahyani, A., Venet, P., Guermazi, A., & Troudi, A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210736 · Cited by 355 · cited 1×
“HESS sizing method for EV application is presented in [19], and for uninterruptable power supply application in [20].”
MethodA Hybrid Fuel Cell Power System
Jin, K., Ruan, X., Yang, M., & Xu, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008336 · Cited by 331 · cited 1×
“PV is preferred in terms of sustainability and reliability, but its generation and stability are easily affected by intermittent operating conditions such as change in irradiance, temperature, humidity, and partial shadings effects [2], [3].”
BackgroundDevelopment of hybrid battery–supercapacitor energy storage for remote area renewable energy systems
Ma, T., Yang, H., & Lu, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.12.008 · Cited by 324 · cited 1×
“[21] presented the application of HESS in remote area RESs.”
MethodGarcía–Triviño, P., García‐Vázquez, C. A., RAMIREZ, L. M. F., Llorens-Iborra, F., & Jurado, F. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2290069 · Cited by 300 · cited 1×
“This includes fuzzy logic control [9], adaptive neuro-fuzzy inference system based control [10], and model predictive control (MPC) [11].”
MethodPower Smoothing of Large Solar PV Plant Using Hybrid Energy Storage
Wang, G., Ciobotaru, M., & Agelidis, V. G. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2305433 · Cited by 298 · cited 1×
“To solve the aforementioned issues, battery energy storage system (BESS) is generally used [4].”
MethodHierarchical Control of Hybrid Energy Storage System in DC Microgrids
Xiao, J., Wang, P., & Setyawan, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2400419 · Cited by 286 · cited 1×
“gies have been reported in the literature [6]–[23].”
BackgroundEl Fadil, H., Giri, F., Guerrero, J. M., & Tahri, A. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2323181 · Cited by 214
Debnath, D., & Chatterjee, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2379584 · Cited by 177 · cited 1×
“With the increased concern about fossil fuel based energy usage, the design of electrical power system focuses on increasing the utilization of renewable energy sources (RESs) [1].”
BackgroundDusmez, S., & Khaligh, A. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2299237 · Cited by 169 · cited 4×
“[14] S. Dusmez and A. Khaligh, “A supervisory power-splitting approach for a new ultracapacitor, battery vehicle deploying two propulsion machines,” IEEE Trans.”
MethodInfluentialCombined Sizing and Energy Management in EVs With Batteries and Supercapacitors
Araújo, R. E., de Castro, R. P., Pinto, C., Melo, P., & Freitas, D. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2318275 · Cited by 154 · cited 1×
“HESS sizing method for EV application is presented in [19], and for uninterruptable power supply application in [20].”
MethodDynamic energy management of micro grids using battery super capacitor combined storage
Sathishkumar, R., Kollimalla, S. K., & Mishra, M. K. (2012) · IEEE India Conference · doi:10.1109/indcon.2012.6420777 · Cited by 146 · cited 5×
“Unlike the conventional control strategy [25]–[27], the power required to balance the overall power flow in the dc link during load and generation”
BackgroundMethodResultInfluentialSelf-citationSupercapacitor Sizing Method for Energy-Controlled Filter-Based Hybrid Energy Storage Systems
Abeywardana, D. B. W., Hredzak, B., Agelidis, V. G., et al. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2552198 · Cited by 137 · cited 1×
“[18] presented a parameter selection technique for the filter based power decoupling method in HESS and SC sizing for microgrid application.”
MethodAbeywardana, D. B. W., Hredzak, B., & Agelidis, V. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2527051 · Cited by 134
Xu, Q., Xiao, J., Wang, P., Pan, X., & Wen, C. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2688391 · Cited by 122 · cited 1×
“Decentralized control strategy for dynamic power sharing between the HESS is presented in [17].”
BackgroundHybrid Energy Storage With Multimode Fuzzy Power Allocator for PV Systems
Feng, X., Gooi, H. B., & Chen, S. X. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2290543 · Cited by 111 · cited 2×
“This includes fuzzy logic control [9], adaptive neuro-fuzzy inference system based control [10], and model predictive control (MPC) [11].”
MethodHredzak, B., Agelidis, V. G., & Demetriades, G. D. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2277518 · Cited by 103 · cited 2×
“This includes fuzzy logic control [9], adaptive neuro-fuzzy inference system based control [10], and model predictive control (MPC) [11].”
MethodModeling and Design of an Oscillatory Current-Sharing Control Strategy in DC Microgrids
Hamzeh, M., Ghazanfari, A., Mohamed, Y. A. I., & Karimi, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2435703 · Cited by 103 · cited 1×
“The cutoff frequency of LPF is chosen to be 2*Π*5 rad/s, as presented in [29].”
MethodOptimization of Charge/Discharge Rates of a Battery Using a Two-Stage Rate-Limit Control
Kollimalla, S. K., Ukil, A., Gooi, H. B., Manandhar, U., & Tummuru, N. R. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2608968 · Cited by 72 · cited 1×
“[16] proposed the two-state rate limit control for HESS application in standalone DC grid system.”
BackgroundSelf-citationStability Analysis of Converter-Connected Battery Energy Storage Systems in the Grid
Bazargan, D., Filizadeh, S., & Gole, A. M. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2337053 · Cited by 66 · cited 1×
“[22] presented the effect in the stability of the converter connected to the battery system due to change in internal resistance and internal voltage of the battery.”
BackgroundAdaptive Rate-Limit Control for Energy Storage Systems
Wu, D., Todd, R., & Forsyth, A. J. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2385043 · Cited by 49
Kim, D., Choi, S., Kim, S., & Choi, B. (2011) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2011.5944449 · Cited by 14
Cited by
Hybrid energy storage system for microgrids applications: A review
Hajiaghasi, S., Salemnia, A., & Hamzeh, M. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.12.017 · Cited by 585
Grid Integration Challenges and Solution Strategies for Solar PV Systems: A Review
Shafiullah, M., Ahmed, S. D., & Al-Sulaiman, F. A. (2022) · IEEE Access · doi:10.1109/access.2022.3174555 · Cited by 473
Babu, T. S., Vasudevan, K. R., Ramachandaramurthy, V. K., Sani, S. B., Chemud, S., & Lajim, R. M. (2020) · IEEE Access · doi:10.1109/access.2020.3015919 · Cited by 354
“Another control technique named FJC is proposed in [26] for control of HESS in DC microgrids.”
BackgroundMethodKhalid, M. (2019) · Energies · doi:10.3390/en12234559 · Cited by 183
Reinforcement Learning Based Energy Management Algorithm for Smart Energy Buildings
Kim, S., & Lim, H. (2018) · Energies · doi:10.3390/en11082010 · Cited by 169
“This hybrid ESS can take both the advantages of battery (high energy density and low cost per kWh) and super-capacitor (quick charging/discharging and extended lifetime) [23].”
Background
Metadata
- Authors
- Manandhar, U., Tummuru, N. R., Kollimalla, S. K., Ukil, A., Beng, G. H., & Chaudhari, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-04
- Volume
- 65
- Issue
- 4
- Pages
- 3286-3295
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2750974078
- Cited by
- 227
- References
- 28
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.