CoChat

Short-Time Fourier Transform Based Transient Analysis of VSC Interfaced Point-to-Point DC System

Open access
Satpathi, Kuntal, Yeap, Yew Ming, Ukil, Abhisek, Geddada, Nagesh · 2018 · IEEE Transactions on Industrial Electronics
Cited by 200

The DOI matches its Crossref record.

Abstract

The transient response of the voltage source converter (VSC) interfaced dc system is significantly different from the ac counterpart. The rapid discharge current from the dc-link capacitors and the vulnerability of the freewheeling diodes during the short circuit in dc grid demand that the transient detection algorithm executes within a few milliseconds. The rapidly rising fault current in the dc grid is expected to have high-frequency components which might be an effective indicator of the transient condition. This paper presents quantitative investigation of the high-frequency components utilizing short-time Fourier transform (STFT) during transient conditions. Detailed operating principles with various factors affecting the STFT operation such as ripple content of the input dc signal and window type and length have been thoroughly investigated. STFT algorithm is able to detect low-impedance faults within 1 ms and high-impedance faults in 2 ms. Moreover, it is able to distinguish between short-circuit fault and less severe transient conditions such as sudden load change. The STFT algorithm is evaluated analytically and subsequently applied to a MATLAB/Simulink based dc test system. It is further validated and substantiated with the real fault current data obtained from a scaled-down experimental testbed. Sensitivity analysis and comparison with the existing frequency-domain-based fault-detection method are done to support the efficacy of the proposed method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2017.2758745

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Satpathi, K., Yeap, Y. M., Ukil, A., & Geddada, N.
Venue
IEEE Transactions on Industrial Electronics
Published
2018-05
Volume
65
Issue
5
Pages
4080-4091
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2763524503
Cited by
200
References
0
FWCI
7.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Short-Time Fourier Transform Based Transient Analysis of VSC Interfaced Point-to-Point DC System. https://app.cochat.ai/papers/10.1109/tie.2017.2758745
The paper
Satpathi, K., Yeap, Y. M., Ukil, A., & Geddada, N. (2018). Short-Time Fourier Transform Based Transient Analysis of VSC Interfaced Point-to-Point DC System. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2758745

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.