The DOI matches its Crossref record.
Impact of Inverter-Interfaced Renewable Energy Generators on Distance Protection and an Improved Scheme
Abstract
With different structures and control strategies, inverter-interfaced renewable energy generators (IIREGs) have different fault characteristics from synchronous generators. This makes the conventional distance protection used in networks with synchronous generators not applicable for transmission lines emanating from IIREGs. Therefore, supported by the fault current analysis, operating performances of distance relays on both sides of the transmission line are unveiled. It reveals the problem that the conventional distance relay on the IIREG side has a high risk of malfunction or refusing to operate. To cope with this adaptability problem, an improved scheme based on time delay and zero-sequence impedance is proposed in this paper. To validate the operating performances of the scheme, a detailed IIREG model is built in a real-time digital simulator, and simulation tests are carried out. Apart from these, a field short-circuit test is performed in a real wind power plant to examine the practical feasibility of the proposed scheme. Both the simulation results and the field test confirm the problem of the conventional distance protection and verify the reliability of the improved scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Pourghasem Gavgani, P., Baghbannovin, S., Mohseni-Bonab, S. M., & Kamwa, I. (2024) · Energies · doi:10.3390/en17061353 · Cited by 19
Metadata
- Authors
- Fang, Y., Jia, K., Yang, Z., Li, Y., & Bi, T.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-09
- Volume
- 66
- Issue
- 9
- Pages
- 7078-7088
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2898302362
- Cited by
- 205
- References
- 0
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Inverter-Interfaced Renewable Energy Generators on Distance Protection and an Improved Scheme. https://app.cochat.ai/papers/10.1109/tie.2018.2873521
- The paper
- Fang, Y., Jia, K., Yang, Z., Li, Y., & Bi, T. (2019). Impact of Inverter-Interfaced Renewable Energy Generators on Distance Protection and an Improved Scheme. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2873521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.