A Continuous Biomedical Signal Acquisition System Based on Compressed Sensing in Body Sensor Networks
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The emerging compressed sensing (CS) holds considerable promise for continuously acquiring biomedical signals in body sensor networks (BSNs), which enables nodes to employ a much lower sampling rate than Nyquist while still able to accurately reconstruct signals. CS-based BSNs are expected to significantly enhance the quality of healthcare and improve the ability of prevention, early diagnosis, and treatment of chronic diseases. However, existing BSNs are still unable to support long-term monitoring in healthcare, as well as providing an energy-efficient low communication burden and inexpensive scheme. Capitalizing on the sparsity of biomedical signals in transfer domains, this paper develops a continuous biomedical signal acquisition system, which explores a sparsification model to find the sparse representation of biomedical signals. The sparsified measurements of signals are wirelessly transmitted to a fusion center through BSNs. Meanwhile, a weighted group sparse reconstruction algorithm is proposed to accurately reconstruct the signals at the fusion center. Simulation results show that, on random sampling over BSN, the proposed group sparse algorithm shows good efficiency, strong stability, and robustness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
Self-citation
Cited by
Yang, G., Xie, L., Mäntysalo, M., Zhou, X., Pang, Z., Xu, L. D., Kao-Walter, S., Chen, Q., & Zheng, L.-R. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307795 · Cited by 696
Self-citationInternet of Things for Enterprise Systems of Modern Manufacturing
Bi, Z., Xu, L. D., & Wang, C. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2300338 · Cited by 672
Self-citationFang, S., Xu, L. D., Zhu, Y., Ahati, J., Pei, H., Yan, J., & Liu, Z. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2302638 · Cited by 559
Self-citationEnd-to-end security scheme for mobility enabled healthcare Internet of Things
Moosavi, S. R., Gia, T. N., Nigussie, E., Rahmani, A. M., Virtanen, S., Tenhunen, H., & Isoaho, J. (2016) · Future Generation Computer Systems · doi:10.1016/j.future.2016.02.020 · Cited by 280
Continuous patient monitoring with a patient centric agent: a block architecture
Uddin, M. A., Stranieri, A., Gondal, I., & Balasubramanian, V. (2018) · IEEE Access · doi:10.1109/access.2018.2846779 · Cited by 264
Metadata
- Authors
- Li, S., Xu, L. D., & Wang, X.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2013-08
- Volume
- 9
- Issue
- 3
- Pages
- 1764-1771
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2099352953
- Cited by
- 81
- References
- 1
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Continuous Biomedical Signal Acquisition System Based on Compressed Sensing in Body Sensor Networks. https://app.cochat.ai/papers/10.1109/tii.2013.2245334
- The paper
- Li, S., Xu, L. D., & Wang, X. (2013). A Continuous Biomedical Signal Acquisition System Based on Compressed Sensing in Body Sensor Networks. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2013.2245334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.