Design, Planning and Management of a Hydrogen-Based Microgrid
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Efficient energy generation and consumption is a key factor to achieve ambitious goals related to air pollution and climate change. Modern electricity networks can include different kind of sources, such as renewable energy sources (RES). Then, hybrid systems are obtained by combining several sources and storage types in the new concept called microgrid (MG). In order to draw the best performance from these hybrid systems, a proper design and operation is essential. The purpose of this paper is to present a detailed report to properly undertake the building and management of a hydrogen MG in a simple and reliable way to continue struggling for more comprehension on the MG operation modes and prevent the reported failures in the literature. The experimental platform developed will provide the valuable knowledge and solid guidelines for future test centers and demonstration plants. The MG, located in Seville, Spain, incorporates an electrolyzer, metal hydride storage, fuel cell, and a battery bank as main components. The developed MG laboratory has been successfully tested. The results indicate reliable operation incorporating the hydrogen and batteries as energy storage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Smart Grid Technologies: Communication Technologies and Standards
Gungor, V. C., Sahin, D., Kocak, T., Ergut, S., Buccella, C., Cecati, C., & Hancke, G. P. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2166794 · Cited by 2,688 · cited 2×
“T HE paradigm of microgrids was introduced by Lasseter [1] as a system approach that views generation and associated loads as a subsystem or microgrid.”
MethodKanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985 · cited 1×
“TheMG energymanagement can be analyzed through two time scales, as stated in [16]: • long-term energy management: it includes production and load forecast, maintenance intervals, disconnection of controllable loads and provision of power reserve capacity.”
BackgroundA review on distributed energy resources and MicroGrid
Jiayi, H., Chuanwen, J., & Rong, X. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.06.004 · Cited by 882 · cited 1×
“Microgrids (MGs) can operate interconnected to themain distribution grid, or in an islanded mode, and they can also be interconnected to other MGs, giving rise to a more complex system [2].”
BackgroundA review on solar-hydrogen/fuel cell hybrid energy systems for stationary applications
Yilanci, A., Dincer, I., & Ozturk, H. K. (2009) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2008.07.004 · Cited by 506 · cited 2×
“Operating thresholds of the hysteresis band have been taken from a real demonstration plant [6].”
BackgroundIpsakis, D., Voutetakis, S., Seferlis, P., Stergiopoulos, F., & Elmasides, C. (2009) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.06.051 · Cited by 436 · cited 1×
“As it has been demonstrated in many studies [18], [19] the most recommended option uses the batteries as the first way of energy storage, due to their higher efficiency.”
BackgroundUlleberg, Ø., Nakken, T., & Eté, A. (2010) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2009.10.077 · Cited by 320 · cited 1×
“A summary of wind-hydrogen plants can be found in [5] and solar hydrogen-power plants are summarized in [6].”
BackgroundOptimized photovoltaic generator–water electrolyser coupling through a controlled DC–DC converter
García‐Valverde, R., Miguel, C., Martínez‐Béjar, R., & Urbina, A. (2008) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.06.015 · Cited by 134 · cited 1×
“The dc converters enable to operate the fuel cell and electrolyzer along smooth power curves by limiting the power slew rate, protecting the equipment from sudden power changes and increasing its lifetime [13], [14].”
BackgroundThe effect of the hysteresis band on power management strategies in a stand-alone power system
Ipsakis, D., Voutetakis, S. S., Seferlis, P., Stergiopoulos, F., Papadopoulou, S., & Elmasides, C. (2008) · Energy · doi:10.1016/j.energy.2008.07.012 · Cited by 98
State-of-charge estimation for lead-acid batteries based on dynamic open-circuit voltage
Ng, K.-S., Moo, C.-S., Chen, Y.-P., & Hsieh, Y.-C. (2008) · 2008 IEEE 2nd International Power and Energy Conference · doi:10.1109/pecon.2008.4762614 · Cited by 86
Cited by
Fueling the future: A comprehensive review of hydrogen energy systems and their challenges
Le, T. T., Sharma, P., Bora, B. J., Tran, V. D., Truong, T. H., Le, H. C., & Nguyen, P. Q. P. (2024) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2023.08.044 · Cited by 784
A review on the role, cost and value of hydrogen energy systems for deep decarbonisation
Parra, D., Valverde, L., Pino, F. J., & Patel, M. K. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.11.010 · Cited by 737
Self-citationEmergence of hybrid energy storage systems in renewable energy and transport applications – A review
Hemmati, R., & Saboori, H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.029 · Cited by 423
Hybrid Optimization for Economic Deployment of ESS in PV-Integrated EV Charging Stations
Chaudhari, K., Ukil, A., Kumar, K. N., Manandhar, U., & Kollimalla, S. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2713481 · Cited by 384
Garcia-Torres, F., & Bordons, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2412524 · Cited by 330
Self-citationDecentralized Power Management of a PV/Battery Hybrid Unit in a Droop-Controlled Islanded Microgrid
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2394351 · Cited by 169
“On the other hand, the microgrids considered in [17] and [18] are composed of one hybrid source and loads, which makes the system more like a standalone power supply, rather than an islanded microgrid, from a control point of view.”
Background
Metadata
- Authors
- Valverde, L., Rosa, F., & Bordons, C.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2013-08
- Volume
- 9
- Issue
- 3
- Pages
- 1398-1404
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2007595950
- Cited by
- 163
- References
- 11
- FWCI
- 13.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.