Physical Layer Security for the Smart Grid: Vulnerabilities, Threats, and Countermeasures
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Smart energy systems are becoming an important component of smart cities. The wide adoption of existing computing technologies and communication standards by a smart energy system exposes it to the plethora of threats that exist in cyberspace. In this article, we investigate the vulnerabilities and threats associated with smart energy system components, including Internet of Things enabled devices, as well as relevant communication standards, and we discuss countermeasures against adversarial attacks. We found that the existing literature has reported various attacks, including modification, denial-of-service, malware, and message replay, which can cause malfunctioning of different components of a smart energy system. In addition, we propose a framework for securing the physical layer of the smart energy system. The framework is based on advanced key generation, machine learning, and physical layer security techniques, which enhance the security of smart energy systems across different applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IoT security: Review, blockchain solutions, and open challenges
Khan, M. A., & Salah, K. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2017.11.022 · Cited by 2,488 · cited 2×
“IoT-enabled smart grid devices, such as LoRaWAN devices, use orthogonal spreading factors along with frequency hopping to prevent jamming attacks [29].”
BackgroundSecurity and privacy in smart city applications: Challenges and solutions
Zhang, K., Ni, J., Yang, K., Liang, X., Ren, J., & Shen, X. S. (2017) · IEEE Communications Magazine · doi:10.1109/mcom.2017.1600267cm · Cited by 638 · cited 1×
“and the data aggregator can decrypt the messages only when it obtains all individual keys correctly [35].”
BackgroundMukherjee, A. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2466548 · Cited by 347
Modeling Cyber-Physical Vulnerability of the Smart Grid With Incomplete Information
Srivastava, A., Morris, T., Ernster, T., Vellaithurai, C., Pan, S., & Adhikari, U. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2232318 · Cited by 169
Cited by
Blockchain for Future Smart Grid: A Comprehensive Survey
Mollah, M. B., Zhao, J., Niyato, D., Lam, K.-Y., Zhang, X., Ghias, A. M. Y. M., Koh, L. H., & Yang, L. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2993601 · Cited by 542
Ahmad, K., Maabreh, M., Ghaly, M., Khan, K., Qadir, J., & Al-Fuqaha, A. (2022) · Computer Science Review · doi:10.1016/j.cosrev.2021.100452 · Cited by 291
Machine learning and data analytics for the IoT
Adi, E., Anwar, A., Baig, Z., & Zeadally, S. (2020) · Neural Computing and Applications · doi:10.1007/s00521-020-04874-y · Cited by 279
Self-citationCybersecurity for Industrial IoT (IIoT): Threats, countermeasures, challenges and future directions
Mekala, S. H., Baig, Z., Anwar, A., & Zeadally, S. (2023) · Computer Communications · doi:10.1016/j.comcom.2023.06.020 · Cited by 111
Self-citation
Metadata
- Authors
- Islam, S. N., Baig, Z., & Zeadally, S.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2019-12
- Volume
- 15
- Issue
- 12
- Pages
- 6522-6530
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2966738299
- Cited by
- 131
- References
- 4
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical Layer Security for the Smart Grid: Vulnerabilities, Threats, and Countermeasures. https://app.cochat.ai/papers/10.1109/tii.2019.2931436
- The paper
- Islam, S. N., Baig, Z., & Zeadally, S. (2019). Physical Layer Security for the Smart Grid: Vulnerabilities, Threats, and Countermeasures. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2019.2931436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.