The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Should the classical variance be used as a basic measure in standards metrology?
Abstract
Since a measurement is no better than its uncertainty, specifying the uncertainty is a very important part of metrology. One is inclined to believe that the fundamental constants in physics are invariant with time and that they are the foundation upon which to build internationl system (SI) standards and metrology. Therefore clearly specifying uncertainties for these physical invariants at state-of-the-art levels should be one of the principal goals of metrology. However, by the very act of observing some physical quantity we may perturb the standard, thus introducing uncertainties. The random deviations in a series of observations may be caused by the measurement system, by environmental coupling or by intrinsic deviations in the standard. For these reasons and because correlated random noise is as commonly occurring in nature as uncorrelated random noise, the universal use of the classical variance, and the standard deviation of the mean may cloud rather than clarify questions regarding uncertainties; i.e., these measures are well behaved only for random uncorrelated deviations (white noise), and white noise is typically a subset of the spectrum of observed deviations. The assumption that each measurement in a series is independent because the measurements are taken at different times should be called into question if, in fact, the series is not random and uncorrelated, i.e., does not have a white spectrum. In this paper, studies of frequency standards, standard-volt cells, and gauge blocks provide examples of long-term random-correlated time series which indicate behavior that is not "white" (not random and uncorrelated). This paper outlines and illustrates a straightforward time-domain statistical approach, which for power-law spectra yields an alternative estimation method for most of the important random power-law processes encountered. Knowing the spectrum provides for clearer uncertainty assessment in the presence of correlated random deviations, the statistical approach outlined also provides a simple test for a white spectrum, thus allowing a metrologist to know whether use of the classical variance is suitable or whether to incorporate better uncertainty assessment procedures, e.g., as outlined in the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Self-citation
Cited by
Atomic physics with super-high intensity lasers
Protopapas, M., Keitel, C. H., & Knight, P. L. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/4/001 · Cited by 816
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Towards a quantum resistance standard based on epitaxial graphene
Tzalenchuk, A., Lara-Avila, S., Kalaboukhov, A., Paolillo, S., Syväjärvi, M., Yakimova, R., Kazakova, O., Janssen, T. J. B. M., Fal'ko, V., & Kubatkin, S. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.474 · Cited by 486
Metadata
- Authors
- Allan, D. W.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 1987-06
- Volume
- IM-36
- Issue
- 2
- Pages
- 646-654
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2079809336
- Cited by
- 237
- References
- 1
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.