Estimation of Human Foot Motion During Normal Walking Using Inertial and Magnetic Sensor Measurements
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A foot motion filtering algorithm is presented for estimating foot kinematics relative to an earth-fixed reference frame during normal walking motion. Algorithm input data are obtained from a foot-mounted inertial/magnetic measurement unit. The sensor unit contains a three-axis accelerometer, a three-axis angular rate sensor, and a three-axis magnetometer. The algorithm outputs are the foot kinematic parameters, which include foot orientation, position, velocity, acceleration, and gait phase. The foot motion filtering algorithm incorporates novel methods for orientation estimation, gait detection, and position estimation. Accurate foot orientation estimates are obtained during both static and dynamic motion using an adaptive-gain complementary filter. Reliable gait detection is accomplished using a simple finite state machine that transitions between states based on angular rate measurements. Accurate position estimates are obtained by integrating acceleration data, which has been corrected for drift using zero velocity updates. Algorithm performance is examined using both simulations and real-world experiments. The simulations include a simple but effective model of the human gait cycle. The simulation and experimental results indicate that a position estimation error of less than 1% of the total distance traveled is achievable using commonly available commercial sensor modules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
introduction to random signals and applied kalman filtering
Brown, R. G., & Hwang, P. Y. (1992) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,365
Pedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399 · cited 1×
“In [19], Foxlin used a foot-mounted IMMU from Inter-”
MethodKuipers, J. B. (1999) · Princeton University Press eBooks · doi:10.1515/9780691211701 · Cited by 1,290
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887 · cited 1×
“In [18], Sabatini described a quaternion-based extended Kalman filter for determining the orientation of a rigid”
MethodZero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662 · cited 1×
“A thorough analysis of gait detection techniques is found in [30].”
MethodAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650 · cited 1×
“[16] assumed that all motion takes place in a sagittal plane.”
BackgroundKuipers, J. (2020) · Princeton University Press eBooks · doi:10.2307/j.ctvx5wc3k · Cited by 642
Activity and location recognition using wearable sensors
Lee, S.-W., & Mase, K. (2002) · IEEE Pervasive Computing · doi:10.1109/mprv.2002.1037719 · Cited by 525
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495 · cited 1×
“Others have incorporated force-sensitive resistors into the shoe or foot-mounted switches, such as in [21], [23], and [24].”
BackgroundBiomechanics and Motor Control of Human Movement
Vélez Día, D., & Moreno Gutiérrez, S. S. (2013) · XIKUA Boletín Científico de la Escuela Superior de Tlahuelilpan · doi:10.29057/xikua.v1i1.1175 · Cited by 380
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334
Xiaoping, Y., Bachmann, E. R., & McGhee, R. B. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.911646 · Cited by 320
Self-citationPersonal Dead-reckoning System for GPS-denied Environments
Ojeda, L., & Borenstein, J. (2007) · 2007 IEEE International Workshop on Safety, Security and Rescue Robotics · doi:10.1109/ssrr.2007.4381271 · Cited by 188 · cited 1×
“In another work by Ojeda and Borenstein [20], error on the order of 2% of distance walked was reported.”
MethodAmbulatory Assessment of Ankle and Foot Dynamics
Schepers, H. M., Koopman, H. F. J. M., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889769 · Cited by 186 · cited 1×
“Others have incorporated force-sensitive resistors into the shoe or foot-mounted switches, such as in [21], [23], and [24].”
BackgroundLevangie, P. K., & Norkin, C. C. (1983) · Cited by 172
Personal Navigation via High-Resolution Gait-Corrected Inertial Measurement Units
Bebek, Ö., Suster, M. A., Rajgopal, S., Fu, M. J., Huang, X., Cavusoglu, M. C., Young, D. J., Mehregany, M., van den Bogert, A. J., & Mastrangelo, C. H. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2046595 · Cited by 160 · cited 2×
“Others have incorporated force-sensitive resistors into the shoe or foot-mounted switches, such as in [21], [23], and [24].”
BackgroundAmbulatory Monitoring of Activities and Motor Symptoms in Parkinson's Disease
Zwartjes, D. G. M., Heida, T., van Vugt, J. P. P., Geelen, J. A. G., & Veltink, P. H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2049573 · Cited by 128
Cavallo, F., Sabatini, A. M., & Genovese, V. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1544967 · Cited by 72
Adaptive-gain complementary filter of inertial and magnetic data for orientation estimation
Calusdian, J., Yun, X., & Bachmann, E. R. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979957 · Cited by 61 · cited 1×
“At or near the corner frequency, the filter output is a fusion of both static and dynamic information [28].”
BackgroundSelf-citationResults of Using a Wireless Inertial Measuring System to Quantify Gait Motions in Control Subjects
Tien, I., Glaser, S. D., Bajcsy, R. K., Goodin, D. S., & Aminoff, M. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2021650 · Cited by 51
Cited by
A Comparative Study on Human Activity Recognition Using Inertial Sensors in a Smartphone
Wang, A., Chen, G., Yang, J., Zhao, S., & Chang, C.-Y. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2545708 · Cited by 324
Stance-Phase Detection for ZUPT-Aided Foot-Mounted Pedestrian Navigation System
Wang, Z., Zhao, H., Qiu, S., & Gao, Q. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2430357 · Cited by 196
“applied an acceleration bias error to correct the acceleration during the swing phase [12].”
BackgroundMethodResultInfluentialInertial/magnetic sensors based pedestrian dead reckoning by means of multi-sensor fusion
Qiu, S., Wang, Z., Zhao, H., Qin, K., Li, Z., & Hu, H. (2018) · Information Fusion · doi:10.1016/j.inffus.2017.04.006 · Cited by 186
“Pedestrian walking distance errors have always been the primary concerns in literature [15] [28] [29], while the limitation of evaluating the overall distance errors is the canceling effect of the positive and negative errors occur in each stride.”
BackgroundResult
Metadata
- Authors
- Yun, X., Calusdian, J., Bachmann, E. R., & McGhee, R. B.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2012-07
- Volume
- 61
- Issue
- 7
- Pages
- 2059-2072
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2116114068
- Cited by
- 169
- References
- 21
- FWCI
- 21.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.