A Review for Conductive Polymer Piezoresistive Composites and a Development of a Compliant Pressure Transducer
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the development process for a new kind of compliant piezoresistive transducer based on carbon-nanotube-filled silicone rubber composite. The methods for the composite fabrication and the sensor probe encapsulation are specified. The piezoresistive mechanism of the composite is researched based on the tunneling effect theory. The calibration and transforming method is designed based on the piezoresistivity of the composite. The signal processing system is developed to realize the data conversion, acquisition, processing, and pressure displaying. The transducer system is tested within the measurement range from 0 to 2 MPa at room temperature. The measuring error is 4% full scale. The transducer system can be used to measure the interlaminar pressure of the industrial equipment. Its key technologies can also be used to fabricate an electronic skin and a robotic haptic sensing system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Organic Nonvolatile Memory Transistors for Flexible Sensor Arrays
Sekitani, T., Yokota, T., Zschieschang, U., Klauk, H., Bauer, S., Takeuchi, K., Takamiya, M., Sakurai, T., & Someya, T. (2009) · Science · doi:10.1126/science.1179963 · Cited by 962
Cited by
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Theory, technology and applications of piezoresistive sensors: A review
Fiorillo, A. S., Critello, C. D., & Pullano, S. A. (2018) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2018.07.006 · Cited by 591
Advanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Zeng, X., Wang, Z., Zhang, H., Yang, W., Xiang, L., Zhao, Z., Peng, L.-M., & Hu, Y. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02518 · Cited by 214
Metadata
- Authors
- Wang, L., & Li, Y.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2013-02
- Volume
- 62
- Issue
- 2
- Pages
- 495-502
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2074575205
- Cited by
- 111
- References
- 1
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.