CoChat

A Review for Conductive Polymer Piezoresistive Composites and a Development of a Compliant Pressure Transducer

Wang, Luheng, Li, Yanling · 2013 · IEEE Transactions on Instrumentation and Measurement
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This paper presents the development process for a new kind of compliant piezoresistive transducer based on carbon-nanotube-filled silicone rubber composite. The methods for the composite fabrication and the sensor probe encapsulation are specified. The piezoresistive mechanism of the composite is researched based on the tunneling effect theory. The calibration and transforming method is designed based on the piezoresistivity of the composite. The signal processing system is developed to realize the data conversion, acquisition, processing, and pressure displaying. The transducer system is tested within the measurement range from 0 to 2 MPa at room temperature. The measuring error is 4% full scale. The transducer system can be used to measure the interlaminar pressure of the industrial equipment. Its key technologies can also be used to fabricate an electronic skin and a robotic haptic sensing system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2012.2215160

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Wang, L., & Li, Y.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2013-02
Volume
62
Issue
2
Pages
495-502
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2074575205
Cited by
111
References
1
FWCI
4.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.