Fully Implantable Multi-Channel Measurement System for Acquisition of Muscle Activity
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
This paper presents intramuscular electromyogram (EMG) signals obtained with a fully implantable measurement system that were recorded during goal directed arm movements. In a first implantation thin film electrodes were epimysially implanted on the deltoideus of a rhesus macaque and the encapsulation process was monitored by impedance measurements. Increase of impedance reached a constant level after four weeks indicating a complete encapsulation of electrodes. EMG recorded with these electrodes yielded a signal-to-noise ratio of about 80 dB at 200 Hz. The EMG recorded during goal-directed arm movements showed a high similarity to movements in the same direction and at the same time presented clear differences between different movement directions in time domain. Six classifiers and seven time and frequency domain features were investigated with the aim of discriminating the direction of arm movement from EMG signals. Reliable recognition of arm movements was achieved for a subset of the movements under investigation only. A second implantation of the whole measurement system for nine weeks demonstrated simple handling during surgery and good biotolerance in the animals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In contrast to surface EMG, implantable EMG has many advantages, such as higher signal quality, less movement artifacts, and the ability to record small and deep muscle activity.[364]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [364]
In the citing paper
“In contrast, surface electrodes generally are more flexible,[364,369] whose morphology in the limited space between this epimysium and the skin is either 1D or 2D thin electrode layers[370,371] or very tiny electrodes (millimeter or even sub-millimeter level).[369,372]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [364]
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“For calculation of signal-to-noise ratio (SNR) power spectral density of the recorded EMG signals was calculated using Welch’s method [40].”
MethodA new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“[43] classified four different contraction patterns using six features calculated on 40 ms long frames of EMG achieving 91.”
MethodMyoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651 · cited 2×
“The observed SNR of 80 dB at 200 Hz is a considerable improvement compared to the SNR < 10 of surface EMG [6].”
BackgroundMethodControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 1×
“Classification of movement direction was based on seven features in time and frequency domain [41]–[44].”
BackgroundStudy of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582 · cited 3×
“Investigations on prosthesis control [42]–[44] evaluated two channels of sEMG and focused on classification of clearly distinguishable contraction patterns that were intentionally generated by human subjects.”
BackgroundControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518 · cited 2×
“Further drawbacks originate from sensitivity to changes in skin conductivity and pickup of external electromagnetic noise [14].”
BackgroundEMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477 · cited 3×
“A threshold between 50 mV and 100 mV was reported in the literature [42].”
BackgroundBioimpedance and Bioelectricity Basics
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374004-5.x0001-3 · Cited by 462 · cited 1×
“They normally have higher polarization impedance [8], although recently developed electrodes yield comparable performance during long-term EMG measurements [9].”
BackgroundSmith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443 · cited 1×
“classification performance [42], [47] the short window length”
Background
Research works printed but not linked: 8
- abu-saleh, 2011, Ein ASIC in 130 nm-Technologie für die Aufnahme von EMG-Signalen zur Ansteuerung einer Prothese, Anal Proc
- abu-saleh, 2010, Ein implantierbares System zur Aufnahme von EMG-Signalen zur Ansteuerung einer Prothese, In Proc BMT
- lewis, 0, Performance of implanted multi-site EMG recording electrodes: In vivo impedance measurements and spectral analysis, Proc of IFESS 2010, 133
- cardona, 2011, Inductive energy transmission system and real-time data link for intelligent implants, In Proc BMT, 56
- lewis, 2012, Acquisition of muscle activity with a fully implantable multi-channel measurement system I2MTC, Proc IEEE I2MTC, 996
- dietl, 2010, Verbundprojekt MyoPlant, In Proc BMT
- willison, 1963, A method for measuring motor unit activity in human muscle, J Physiol, 168, 35
- rafolt, 1997, An implantable multichannel telemetry system, Proc XIV Int Symp Biotelemetry, 277
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
“94 ; MIRA, ref.”
Self-citationHand Gesture Recognition Using Three-Dimensional Electrical Impedance Tomography
Jiang, D., Wu, Y., & Demosthenous, A. (2020) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2020.3006430 · Cited by 80
“3006430 electrodes for intramuscular [3], epimysial [4] and intraneural recording [5] can achieve in-depth signal acquisition at higher resolution, but their implementation is limited due to their invasiveness.”
BackgroundApplication of Min-Max Normalization on Subject-Invariant EMG Pattern Recognition
Islam, M. J., Ahmad, S., Haque, F., Reaz, M. B. I., Bhuiyan, M. A. S., & Islam, M. R. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3220286 · Cited by 73
“So, the EMG signal reflects the functional state of hand movements [1], [2].”
BackgroundControl of a Robotic Hand Using a Tongue Control System—A Prosthesis Application
Johansen, D., Cipriani, C., Popović, D. B., & Struijk, L. N. S. A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2517742 · Cited by 75
“is the electromyogram (EMG) signal; several studies have been carried out using surface EMG [1]–[9] and intramuscular [10], [11] recordings.”
BackgroundMaterials and Biomedical Applications of Implantable Electronic Devices
Liu, Y., Yu, Q., Li, Y., & Cui, Y. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200853 · Cited by 67
Motor unit drive: a neural interface for real-time upper limb prosthetic control
Twardowski, M. D., Roy, S. H., Li, Z., Contessa, P., Luca, G. D., & Kline, J. C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaeb0f · Cited by 69
“…nerve or muscle integrity; (2) the management of increased health-risks to an aging population of people with limb-loss; and (3) the accommodation of substantially greater health costs by the prosthesis care system (Baker et al 2010, Schultz and Kuiken 2011, Lewis et al 2013, Pasquina et al 2015).”
BackgroundNovel Noncontact Dry Electrode With Adaptive Mechanical Design for Measuring EEG in a Hairy Site
Chen, Y., Lin, B., & Pan, J. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2459531 · Cited by 56
Bergmeister, K. D., Vujaklija, I., Muceli, S., Sturma, A., Hruby, L. A., Prahm, C., Riedl, O., Salminger, S., Manzano-Szalai, K., Aman, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00421 · Cited by 52
“…tested in extensive pre-clinical large animal trials, showing good biocompatibility and stable electrode impedance over the course of several months, and reliable acquisition of multiple adjacent EMG signals (Poppendieck et al., 2011; Lewis et al., 2013a; Bergmeister K. D. et al., 2016).”
BackgroundSelf-citationWireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 53
A Novel Algorithm for EMG Signal Processing and Muscle Timing Measurement
Pasinetti, S., Lancini, M., Bodini, I., & Docchio, F. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2434097 · Cited by 48
“, low-pass, bandpass, or moving average filtering [6]); 2) a baseline measurement stage (performed measuring the signal amplitude during muscle relaxation or during the subject’s maximal voluntary contraction [7], [8]); and 3) a threshold computation stage (computed using the standard deviation of the baseline value).”
MethodA Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control
Hahne, J. M., Farina, D., Jiang, N., & Liebetanz, D. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00114 · Cited by 38
Cisnal, A., Fraile, J. C., Turiel, J. P., Muñoz-Martínez, V. F., Müller, C., & Ihmig, F. R. (2018) · Sensors · doi:10.3390/s18124152 · Cited by 37
“In this case, the electrode design allows for epimysial implantation (the electrode is placed underneath the epimysium, which is a sheath of fibrous elastic tissue surrounding a muscle) [30].”
BackgroundLong-term decoding of movement force and direction with a wireless myoelectric implant
Morel, P., Ferrea, E., Taghizadeh, B., Audí, J. M. C., Ruff, R., Hoffmann, K., Lewis, S., Russold, M., Dietl, H., Saleh, L. A., et al. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016002 · Cited by 38
“The reach targets (1 cm radius circle, 3 cm tolerance radius) were uniformly distributed on a circle centered on the fixation target (radius 90 mm) [18].”
BackgroundMethodSelf-citationAkhmadeev, K., Yu, T., Carpentier, É. L., Aoustin, Y., & Farina, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2953680 · Cited by 29
“However, in clinical and basic physiological applications, there is a growing interest in multi-channel electrode systems [11]–[14].”
BackgroundTogo, S., Murai, Y., Jiang, Y., & Yokoi, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-50112-4 · Cited by 29
Wearable super-resolution muscle–machine interfacing
Wang, H., Zuo, S., Cerezo‐Sánchez, M., Arekhloo, N. G., Nazarpour, K., & Heidari, H. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1020546 · Cited by 25
“The blurring effect causes relatively poor spatial resolution, especially for large-size electrodes (Lewis et al., 2013; Afsharipour et al., 2019).”
BackgroundToward the Development of User-Centered Neurointegrated Lower Limb Prostheses
Barberi, F., Anselmino, E., Mazzoni, A., Goldfarb, M. T., & Micera, S. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3309328 · Cited by 32
“Various implantable EMG technologies are now commercially available, such as IMES electrodes [128], MIRA [129], iSens [130] and MyoPlant [131], [132].”
MethodMetric-Based Muscle Synergy Consistency for Upper Limb Motor Functions
Sheng, Y., Zeng, J., Liu, J., & Liu, H. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3132345 · Cited by 29
Intelligent Knee Prostheses: A Systematic Review of Control Strategies
Li, L., Wang, X., Meng, Q., Chen, C., Sun, J., & Yu, H. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00169-1 · Cited by 24
Deng, Z., Zhang, X., Chen, X., Chen, X. '., Chen, X., & Yin, E. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3244849 · Cited by 28
“Many studies focus on appropriate EMG measurements and instrumentations to estimate the kinematic characteristics of human body toward myoelectric control [8], [9], [10], [11], [12], [13], [14], [15], [16], [17].”
BackgroundBergmeister, K. D., Hader, M., Lewis, S., Russold, M.-F., Schiestl, M., Manzano-Szalai, K., Roche, A. D., Salminger, S., Dietl, H., & Aszmann, O. C. (2015) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000001926 · Cited by 23
Self-citationCisnal, A., Ihmig, F. R., Fraile, J. C., Turiel, J. P., & Muñoz-Martínez, V. F. (2019) · Sensors · doi:10.3390/s19122725 · Cited by 20
“epimysially implanted; the electrode is placed underneath the epimysium—a sheath of fibrous elastic tissue surrounding a muscle [26].”
BackgroundFacial Muscle Activity: High-Sensitivity Noncontact Measurement Using Laser Doppler Vibrometry
Casaccia, S., Sirevaag, E. J., Frank, M. G., O’Sullivan, J. A., Scalise, L., & Rohrbaugh, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3060564 · Cited by 15
“The level at which this inflection point appears is a function of the muscle fiber composition [40], [41].”
BackgroundNg, K. A., Rusly, A., Gammad, G. G. L., Le, N., Liu, S.-C., Leong, K.-W., Zhang, M., Ho, J. S., Yoo, J., & Yen, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3009088 · Cited by 14
“a much smaller form factor than earlier reported works [5], [7] and reduces the possibility of early device failure points arising from multiple discrete component integration.”
BackgroundMethodResultInfluentialWang, C., Sivan, M., Wang, D., Zhang, Z., Li, G., Bao, T., & Xie, S. Q. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3173273 · Cited by 11
Tereshenko, V., Dotzauer, D. C., Schmoll, M., Harnoncourt, L., Rojas, G. C., Gfrerer, L., Eberlin, K. R., Austen, W. G., Blumer, R., Farina, D., et al. (2024) · Science Advances · doi:10.1126/sciadv.adj3872 · Cited by 11
“…systems for surface EMG ( 26 , 27 ) along with promising outcomes from wireless intramuscular sensors (i.e., implantable myoelectric sensor, Myoplant, or myoelectric implantable recording array) may allow deciphering of complex motor commands from several neural sources ( 28 – 32 ).”
Lambrecht, J. M., Cady, S. R., Peterson, E. J., Dunning, J. L., Dinsmoor, D. A., Pape, F., Graczyk, E. L., & Tyler, D. J. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad56c9 · Cited by 12
“Other clinically reported implantable topologies include non-distributed devices such as the MyoPlant [42], Myoelectric Implantable Recording Array [26, 43], Implanted Stimulator Telemeter (IST-12) [44] and independent wireless units such as the IMES® [25] recording devices and BION® [45]…”
MethodVostrikov, S., Ingolfsson, T. M., Hafthorsdottir, S., Leitner, C., Magno, M., Luca Benini, C., & Cossettini, A. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3335535 · Cited by 8
“M EASURING muscle activity during movement is of paramount importance for many applications, including rehabilitation [1], [2], augmented reality [3], or prostheses control [4], [5], as well as for removing muscle artifacts from biosignals [6].”
BackgroundRobbiani, S., Tarantini, F., Ventura, L., Veneroni, C., Draghi, L., Dahl, M. J., Pillow, J. J., & Dellacà, R. L. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3144212 · Cited by 8
“tion trade-off as reported in the literature [18]–[20].”
BackgroundVujaklija, I., & Farina, D. (2022) · Springer eBooks · doi:10.1007/978-3-031-10355-1_41 · Cited by 8
Continuously Operating Biosensor and Its Integration into a Hermetically Sealed Medical Implant
Birkholz, M., Glogener, P., Glös, F., Basmer, T., & Theuer, L. (2016) · Micromachines · doi:10.3390/mi7100183 · Cited by 8
“This holds in a comparable manner for animal models that are frequently used for preliminary tests of human medical implants [12,13].”
ResultZhang, D., Chen, X., Li, T., Yang, H., Yu, J., & Xie, P. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3650289 · Cited by 7
“Special attention should be paid to the fact that a threshold needs to be set during the computation of WAMP to distinguish when the signal shows large fluctuations, and the threshold chosen in this article is 50 mV [30].”
Highly Accurate Real-Time Decomposition of Single Channel Intramuscular EMG
Yu, T., Akhmadeev, K., Carpentier, É. L., Aoustin, Y., & Farina, D. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3104621 · Cited by 10
Becerra-Fajardo, L., Minguillón, J., Krob, M. O., Rodrigues, C., González-Sánchez, M., Megía‐García, Á., Redondo-Galán, C., Henares, F. G., Comerma-Montells, A., del‐Ama, A. J., et al. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01295-5 · Cited by 11
A 4×32-Channel Neural Recording System for Deep Brain Stimulation Systems
Kim, S., Na, S.-I., Yang, Y., Kim, H., Kim, T., Cho, J. S., Kim, J.-H., Chang, J. W., & Kim, S. (2017) · JSTS Journal of Semiconductor Technology and Science · doi:10.5573/jsts.2017.17.1.129 · Cited by 6
“It is now common for neuroscientists and clinicians to observe the behavior of diverse signals as part of their research, and this has motivated the development of lownoise, low-power neural recording systems [1-4].”
BackgroundLewis, S., Hahn, M., Klein, C., Russold, M.-F., Ruff, R., Hoffmann, K. ‐., Unger, E., Lanmüller, H., Aszmann, O. C., Dietl, H. A., et al. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2013-4368 · Cited by 6
Self-citationEvaluation of Commercial Connectors for Active Neural Implants
Lancashire, H. T., Habibollahi, M., Jiang, D., & Demosthenous, A. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441072 · Cited by 5
“for implantation; however, these connectors are commonly used in preclinical designs of both implants [5], [7], [8], [10], and on external head-stages [6], [11].”
BackgroundDigital Sensing Systems for Electromyography
Aghchehli, E., Kyranou, I., Dyson, M., & Nazarpour, K. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3435740 · Cited by 7
“Moreover, the EMG signals have been utilised in a wide range of animal studies [5], [21], [22].”
MethodMulti-channel EMG recording and muscle stimulation electrodes for diagnosis and treatment of tremor
Poppendieck, W., Hoffmann, K., Rocón, E., Pons, J. L., Muceli, S., Dideriksen, J. L., & Farina, D. (2014) · Annual Conference of the International Functional Electrical Stimulation Society (IFESS) · doi:10.1109/ifess.2014.7036739 · Cited by 3
“Polyimide thin-film technology has been established as a method to fabricate highly flexible, microstructured electrode systems for both the neural [7] and the muscular system [8].”
MethodSelf-citationWireless Power Transfer to Randomly Distributed Implants via Homogeneous Magnetic Fields
Alexandrov, G., & Rabaey, J. M. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8918735 · Cited by 3
“Electrodes connect via long subcutaneous wires [4] or are integrated on the implant [5], while an external transmitter provides energy to the implant.”
BackgroundImplantable Myoelectric Sensors for Prosthetic Control
Gstoettner, C., Salminger, S., Bergmeister, K. D., Willensdorfer, A., Aman, M., & Aszmann, O. C. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_14 · Cited by 4
Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle Using a Bone-anchored Device
Lancashire, H. T., Al-Ajam, Y., Dowling, R., Pendegrass, C. J., & Blunn, G. W. (2019) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000002391 · Cited by 4
Lee, H., Lee, Y., Jiang, L., Chen, J., Lam, W. L., & Lo, Y. T. (2025) · Advanced technology in neuroscience . · doi:10.4103/atn.atn-d-25-00007 · Cited by 9
High-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
Fully Implantable Multichannel EMG Measurement System: First Results
Lewis, S., Russold, M., Hahn, M., & Aszmann, O. C. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-319-08072-7_12 · Cited by 2
Self-citationZhu, Z., & Oyadiji, S. O. (2016) · ACM Transactions on Embedded Computing Systems · doi:10.1145/2790300 · Cited by 2
Yu, T., Muceli, S., Akhmadeev, K., Carpentier, É. L., Aoustin, Y., & Farina, D. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3556853 · Cited by 2
“Recent electrode technology allows the detection of iEMG signals by multi-channel micro arrays [23], [39], [40], [41].”
A SIC design of an implantable system for improved control of hand prosthesis
Nikas, A., Klein, L., Holzberger, A., Hauer, J., Voelker, M., Hoppe, C., Ruff, R., & Hoffmann, K. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833811 · Cited by 1
“A number of research has been done proposing implantable recording systems [1] [2], which solve typical problems of surface based EMG systems such as, varying connectivity, high sensitivity to interference and low selectivity.”
BackgroundSelf-citation(2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2264873
Becerra-Fajardo, L., Minguillón, J., Krob, M. O., Rodrigues, C., González-Sánchez, M., Megía-García, Á., Galán, C. R., Henares, F. G., Comerma, A., del‐Ama, A. J., et al. (2024) · Figshare · doi:10.6084/m9.figshare.24940697
Becerra-Fajardo, L., Minguillón, J., Krob, M. O., Rodrigues, C., González-Sánchez, M., Megía-García, Á., Galán, C. R., Henares, F. G., Comerma, A., del‐Ama, A. J., et al. (2024) · Figshare · doi:10.6084/m9.figshare.24940983
On the robustness of EMG tensor completion under various missing patterns
Liang, T., Jia, H., Li, C., Caiafa, C. F., Himeno, R., Kushihashi, Y., Solé‐Casals, J., & Sun, Z. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110028
Metadata
- Authors
- Lewis, S., Russold, M., Dietl, H., Ruff, R., Audi, J. M. C., Hoffmann, K.-P., Abu-Saleh, L., Schroeder, D., Krautschneider, W. H., Westendorff, S., Gail, A., Meiners, T., & Kaniusas, E.
- Affiliations
- Otto Bock Healthcare Products, Vienna, Austria
- Ottobock (Austria) (AT)
- Fraunhofer Institute for Biomedical Engineering (DE)
- Fraunhofer Institute for Biomedical Engineering (IBMT), Sankt Ingbert, Germany
- Hamburg University of Technology, Hamburg, Germany
- Hamburg University of Technology (DE)
- University of Göttingen (DE)
- Werner-Wicker-Klinik (DE)
- Vienna University of Technology, Vienna, Austria
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2013-07
- Volume
- 62
- Issue
- 7
- Pages
- 1972-1981
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2052543545
- Cited by
- 52
- References
- 41
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 7 · 2021: 7 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 3 · 2016: 5 · 2015: 4 · 2014: 2 · 2013: 2
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- GRO (submittedVersion)
- tub.dok (Hamburg University of Technology) (submittedVersion)
- Funders
- Medizinische Universität Wien
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- intramuscular electromyography, thin film electrodes, electrode encapsulation, impedance monitoring, rhesus monkeys, deltoid muscle
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.