Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Impact of Skin–Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes

Taji, Bahareh, Shirmohammadi, Shervin, Groza, Voicu, Batkin, Izmail·2014·IEEE Transactions on Instrumentation and Measurement

Abstract

Physicians' understanding of biosignals as measured with medical instruments becomes the foundation of their decisions and diagnoses of patients, as they rely strongly on what the instruments show. Thus, it is critical and very important to ensure that the instruments' recordings exactly reflect what is happening in the patient's body so that the acquired signal is the real one or at least as close to the real in-body signal as possible. This is such an important issue that sometimes physicians use invasive measurements to obtain the real biosignal. Generating an in-body signal from what a measurement device shows is called “signal purification” or “reconstruction” and can be done only when we have adequate information about the interface between the body and the monitoring device. In this paper, first, we present a device that we developed for electrocardiogram (ECG) acquisition and transfer to PC. To evaluate the performance of the device, we use it to measure ECG and apply conductive textile as our ECG electrode. Then, we evaluate ECG signals captured by different electrodes, specifically traditional gel Ag/AgCl and dry golden plate electrodes, and compare the results, allowing us to investigate if ECG measured with the device is proper for applications where no skin preparation is allowed, such as ECG-assisted blood pressure monitoring devices. Next, we propose a method to reconstruct the ECG signal from the signal acquired by our device, with respect to the interface characteristics and their relation to the ECG. The interface in this paper is skin-electrode interface for conductive textiles. In the last stage of this paper, we explore the effects of pressure on skin-electrode interface impedance and its parametrical variation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2013.2289072

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 180

Metadata

Authors
Taji, B., Shirmohammadi, S., Groza, V., & Batkin, I.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2014-06
Volume
63
Issue
6
Pages
1412-1422
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2138962073
Cited by
180
References
1
FWCI
4.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Skin–Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes. https://app.cochat.ai/papers/10.1109/tim.2013.2289072
The paper
Taji, B., Shirmohammadi, S., Groza, V., & Batkin, I. (2014). Impact of Skin–Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2013.2289072

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.