Cited by 418Non-Invasive Vital Sign MonitoringWireless Body Area NetworksECG Monitoring and Analysis

A wireless wearable ECG sensor for long-term applications

Nemati, Ebrahim, Deen, M., Mondal, Tapas·2012·IEEE Communications Magazine

Abstract

Ubiquitous vital signs sensing using wireless medical sensors are promising alternatives to conventional, in-hospital healthcare systems. In this work, a wearable ECG sensor is proposed. This sensor system combined an appropriate wireless protocol for data communication with capacitive ECG signal sensing and processing. The ANT protocol was used as a low-data-rate wireless module to reduce the power consumption and size of the sensor. Furthermore, capacitive ECG sensing is a simple technique that avoids direct contact with the skin and provides maximum convenience to the user. In our work, small capacitive electrodes were integrated into a cotton T-shirt together with a signal processing and transmitting board on a two-layer standard printed circuit board design technology. The entire system has small size, is thin, and has low power consumption compared to recent ECG monitoring systems. In addition, appropriate signal conditioning and processing were implemented to remove motion artifacts. The acquired ECG signals are comparable to ones obtained using conventional glued-on electrodes, and are easily read and interpreted by a cardiologist.

Integrity signals

Registry

Crossref · 10.1109/mcom.2012.6122530

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Nemati, E., Deen, M., & Mondal, T.
Affiliations
McMaster University (CA)
Venue
IEEE Communications Magazine
Published
2012-01
Volume
50
Issue
1
Pages
36-43
ISSN
0163-6804 (ISSN-L)
OpenAlex
W2143516309
Cited by
418
References
0
Citations by year
2026: 12 · 2025: 23 · 2024: 25 · 2023: 28 · 2022: 37 · 2021: 46 · 2020: 40 · 2019: 47 · 2018: 40 · 2017: 28 · 2016: 22 · 2015: 19 · 2014: 17 · 2013: 26 · 2012: 8
FWCI
12.75
Type
journal article
Language
en
Open access
closed
Locations
IEEE Communications Magazine (publishedVersion)
Funders
  • Canada Research Chairs
  • Natural Sciences and Engineering Research Council of Canada
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
wearable ECG sensors, long-term ECG monitoring, motion artifact removal, printed circuit board design, low-power sensor systems, vital signs monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review