Cited by 35ECG Monitoring and AnalysisImbalanced Data Classification TechniquesArtificial Intelligence in Healthcare

Generating Healthcare Time Series Data for Improving Diagnostic Accuracy of Deep Neural Networks

Maweu, Barbara Mukami, Shamsuddin, Rittika, Dakshit, Sagnik, Prabhakaran, Balakrishnan·2021·IEEE Transactions on Instrumentation and Measurement

Abstract

Data scarcity and class imbalance are common occurrences in healthcare datasets and have an adverse effect on classification performance of machine learning models. Artificial data generation in various applications can be used to handle these challenges. This article proposes a guided evolutionary synthesizer (GES), a tool derived from principles of genetic algorithm, and designed to generate artificial healthcare time series data for improving classification performance of machine learning models. We conducted a series of promising and confirmatory preliminary experiments performance using traditional machine learning and nonresidual convolutional neural network models to evaluate the effectiveness of GES synthetic on data classification. Motivated by the preliminary results, we conducted eight detailed experiments using residual neural network (ResNet), which demonstrated the flexibility of GES and the effectiveness of GES synthetic data in improving the classification performance of deep neural networks. These experiments use GES generated electrocardiogram (ECG) and electroencephalogram (EEG) datasets. Our findings show that models trained with GES synthetic data performed better than models trained with regular perturbed data, had better diagnostic performance for both EEG and ECG datasets, achieved better performance with lower training volume for EEG dataset, eased learning biases seen in the literature for ECG normal sinus and premature ventricular complex rhythms, and had better classification outcomes than comparable related work models trained with similar ECG classes.

Integrity signals

Registry

Crossref · 10.1109/tim.2021.3077049

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Authors
Maweu, B. M., Shamsuddin, R., Dakshit, S., & Prabhakaran, B.
Affiliations
  • The University of Texas at Dallas (US)
  • Oklahoma State University (US)
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2021
Volume
70
Pages
1-15
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W3158181349
Cited by
35
References
42
Citations by year
2026: 3 · 2025: 9 · 2024: 7 · 2023: 11 · 2022: 5
FWCI
3.89
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Instrumentation and Measurement (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Computer Science › Artificial Intelligence › Imbalanced Data Classification Techniques
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
synthetic data generation, genetic algorithm, data scarcity, class imbalance, ECG classification, EEG classification, ResNet, diagnostic accuracy, data augmentation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review