1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography
Open accessThe DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Abstract
We present the development of a low-noise, fundamental-mode, orthogonal fluxgate magnetometer with four amorphous, annealed ferromagnetic wires. The 1-Hz noise obtained in the open and closed loop is as low as 0.75 and 1.5 pTrms/$\surd $Hz, respectively, with the white noise level about 0.6 pTrms/$\surd $Hz. This is to the best of our knowledge the lowest figure published for a fluxgate magnetometer so far. By using the annealed sensor cores, we also found the offset drift to decrease approximately six times to 2.5 nT/K. We compared the instrument performance to a low-noise observatory magnetometer when doing geomagnetic measurements and show that it is fully suitable for measurements at mHz frequencies, e.g., magnetotellurics. The magnetometer performance enables room-temperature, unshielded magnetocardiography. With a gradiometric arrangement of two sensors, we were able to perform an MCG measurement in ambient field, and even without averaging, the signal could be clearly resolved.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Magnetotelluric Method: Theory and Practice
(2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139020138 · Cited by 702 · cited 1×
“They are used at geomagnetic observatories [1], for navigation and prospection [2], attitude correction, and scientific experiments in aerospace [3], in magnetotellurics [4], [5], nondestructive testing and evaluation [6], nanoparticle detection [7], and in other subjects where vectorial response to magnetic fields an…”
BackgroundDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Alem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4797 · Cited by 182
Orthogonal fluxgate mechanism operated with dc biased excitation
Sasada, I. (2002) · Journal of Applied Physics · doi:10.1063/1.1451899 · Cited by 123 · cited 1×
“They were introduced by Sasada in 2001 [15] and since then the parameters have continuously improved – the noise decreased from the initial 10 pT down to about 1.5-2 pT rms / √ Hz for laboratory devices [17]; with the help of core annealing, sub-pT noise was reported recently [18].”
InfluentialMiniaturized digital fluxgate magnetometer for small spacecraft applications
Forslund, Å., Belyayev, S., Ivchenko, N., Olsson, G., Edberg, T., & Marusenkov, A. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/19/1/015202 · Cited by 64 · cited 1×
“They are used at geomagnetic observatories [1], for navigation and prospection [2], attitude correction and scientific experiments in aerospace [3], in magnetotellurics [4][5], non-destructive testing and evaluation [6], nanoparticle detection [7] and in other subjects, where vectorial response to…”
Flux-Gate Magnetometers Design Peculiarities
Korepanov, V. E., & Marusenkov, A. (2012) · Surveys in Geophysics · doi:10.1007/s10712-012-9197-8 · Cited by 55 · cited 1×
“As for parallel-type fluxgates, the state-of-the art magnetometers exhibit noise level about 3-4 pT rms / √ Hz at 1 Hz [9][11][12].”
BackgroundLow-noise flux-gate magnetic-field sensors using ring- and rod-core geometries
Koch, R. H., & Rozen, J. R. (2001) · Applied Physics Letters · doi:10.1063/1.1358852 · Cited by 54 · cited 1×
“1-pT noise was obtained with cross-correlation measurements and special sensor arrangement in [13], however the principle was not exploited any further.”
MethodReduction of Noise in Fundamental Mode Orthogonal Fluxgates by Optimization of Excitation Current
Butta, M., Yamashita, S., & Sasada, I. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2152379 · Cited by 43 · cited 2×
“Overview of applications of 1-pT level sensors - from [16] We have to state that the generally accepted disadvantage of fundamental-mode fluxgates is their offset-drift - about 50 nT/K was shown in [17].”
BackgroundInfluentialSelf-citationDependence of sensitivity and noise of fluxgate sensors on racetrack geometry
Hinnrichs, C., Stahl, J., Kuchenbrandt, K., & Schilling, M. (2001) · IEEE Transactions on Magnetics · doi:10.1109/20.951028 · Cited by 40
Research works printed but not linked: 6
- technlogies, 2018, General Geophysical Devices
- pappas, 2008, High Sensitivity Magnetic Field Sensor Technology Overview
- hong, 2016, The temperature stability of LeMI-025 1-second variometer: Case study in the icheon observatory, J Indian Geophys Union, 2, 42
- pedersen, 2016, The FGE magnetometer and the INTERMAGNET 1 second standard, J Ind Geophys Union, 2, 30
- 2018, AD24USB/AD24ETH—Data Acquisition Modules
- 2019, Noise Reduction in AD24USB
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Many efforts have been made to develop such kinds of mag-netometers, such as the induction coil magnetometer ( 28 ), fluxgate magnetometers ( 29 ), and magnetoresistive magnetometers ( 30 , 31 ).”
Recent Progress of Fluxgate Magnetic Sensors: Basic Research and Application
Wei, S., Liao, X., Zhang, H., Pang, J., & Zhou, Y. (2021) · Sensors · doi:10.3390/s21041500 · Cited by 123
“The arrangement of the MCG measurement is shown in Figure 4 [25].”
BackgroundMethodInfluentialQuantitative Evaluation for Magnetoelectric Sensor Systems in Biomagnetic Diagnostics
Elzenheimer, E., Bald, C., Engelhardt, E., Hoffmann, J., Hayes, P., Arbustini, J., Bahr, A., Quandt, E., Höft, M., & Schmidt, G. U. (2022) · Sensors · doi:10.3390/s22031018 · Cited by 67
“magnetometers [3,4], xMR sensors [5], orthogonal fluxgates [6], and many more.”
BackgroundSQUIDs for magnetic and electromagnetic methods in mineral exploration
Stolz, R., Schiffler, M., Becken, M., Thiede, A., Schneider, M., Chubak, G., Marsden, P., Bergshjorth, A. B., Schaefer, M. O., & Terblanche, O. (2022) · Mineral Economics · doi:10.1007/s13563-022-00333-3 · Cited by 65
Exchange biased surface acoustic wave magnetic field sensors
Schell, V., Spetzler, E., Wolff, N., Bumke, L., Kienle, L., McCord, J., Quandt, E., & Meyners, D. (2023) · Scientific Reports · doi:10.1038/s41598-023-35525-6 · Cited by 39
Metadata
- Authors
- Janosek, M., Butta, M., Dressler, M., Saunderson, E., Novotny, D., & Fourie, C.
- Affiliations
- Czech Technical University in Prague (CZ)
- South African National Space Agency (ZA)
- Stellenbosch University (ZA)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2020-05
- Volume
- 69
- Issue
- 5
- Pages
- 2552-2560
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2981880989
- Cited by
- 70
- References
- 28
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 14 · 2023: 6 · 2022: 17 · 2021: 16 · 2020: 3
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Czech Technical University Digital Library (Czech Technical University in Prague) (acceptedVersion, other-oa)
- Funders
- Grantová Agentura České Republiky (16-10591Y (Magnetic Gradiometer Based on Fundamental Mode Orthogonal Fluxgate))
- Czech Technical University in Prague through the Mobility Grant, International Mobility of Researches in CTU (CZ.02.2.69/0.0/0.0/16_027/0008465)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- fluxgate magnetometer, geomagnetic observations, magnetocardiography, magnetotellurics, offset drift, white noise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography. https://app.cochat.ai/papers/10.1109/tim.2019.2949205
- The paper
- Janosek, M., Butta, M., Dressler, M., Saunderson, E., Novotny, D., & Fourie, C. (2020). 1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2019.2949205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.